Energy, exergy, environment and economic (4E) analysis of PV/T module assisted vapor compression refrigeration system: An experimental study

Despite the rise in the prices of fossil fuels, the increase in their demand, and damaging the environment, a large part of the world's energy needs have been today met by fossil fuels. In this direction, interest in renewable energy sources has increased. Solar energy stands out among renewable energy sources because it is endless and clean. However, today, the use of solar energy is not used alone, but in combination with other thermal energy systems. In building applications, it is mostly used in heating, refrigeration, and HVAC systems, which have a high part in energy consumption. In this study, the solar energy and cooling system were not used separately as in previous studies but were used as a hybrid. The focus was on increasing the performance of both systems by operating them together. In this study, energy, exergy, thermoeconomic, and environmental analyses were applied to the PV/T-assisted vapor compression refrigeration system (PV/T-VCRS) at different storage temperatures (25 °C, 30 °C, and 35 °C). As a result, an 8.5 % lower surface temperature of the module in PV/T-VCRS 25 °C was measured compared to PV/T-VCRS 30 °C and 35 °C. In direct proportion to the module surface temperatures, 13 % better electrical efficiency was obtained in PV/T-VCRS 25 °C compared to 30 °C and 35 °C. The COP value increased by 15.46 % in PV/T-VCRS 25 °C compared to 30 °C and 35 °C. A 13 % improvement in exergy efficiency was observed in PV/T-VCRS 25 °C compared to 30 °C and 35 °C. The enviroeconomic parameter PV/T-VCRS is calculated as 15.17 ¢/h, 16.52 ¢/h, and 17.6 ¢/h for 25 °C, 30 °C and 35 °C. Another advantage of the system is that hot water is obtained at set temperatures. In PV/T-VCRS, 475 L, 300 L, and 210 L of hot water were obtained at 25 °C, 30 °C, and 35 °C, respectively. As a result, the performance of the PV/T-VCRS was good, with the added benefit of performing close to the performances when PV/T and VCRS were used separately.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-09-10
DOI
https://doi.org/10.1016/j.heliyon.2024.e37690
Citations
10
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
2.13
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy, exergy, environment and economic (4E) analysis of PV/T module assisted vapor compression refrigeration system: An experimental study

Ali Etem Gürel, Ferzan Katırcıoğlu, Gökhan Yıldız, Ümit Ağbulut
10 citations
Heliyon
Refrigeration and Air Conditioning Technologies
2.13
article

Energy, exergy, environment and economic (4E) analysis of PV/T module assisted vapor compression refrigeration system: An experimental study

Ali Etem Gürel, Ferzan Katırcıoğlu, Gökhan Yıldız, Ümit Ağbulut
article en
10 citations

Abstract

Despite the rise in the prices of fossil fuels, the increase in their demand, and damaging the environment, a large part of the world's energy needs have been today met by fossil fuels. In this direction, interest in renewable energy sources has increased. Solar energy stands out among renewable energy sources because it is endless and clean. However, today, the use of solar energy is not used alone, but in combination with other thermal energy systems. In building applications, it is mostly used in heating, refrigeration, and HVAC systems, which have a high part in energy consumption. In this study, the solar energy and cooling system were not used separately as in previous studies but were used as a hybrid. The focus was on increasing the performance of both systems by operating them together. In this study, energy, exergy, thermoeconomic, and environmental analyses were applied to the PV/T-assisted vapor compression refrigeration system (PV/T-VCRS) at different storage temperatures (25 °C, 30 °C, and 35 °C). As a result, an 8.5 % lower surface temperature of the module in PV/T-VCRS 25 °C was measured compared to PV/T-VCRS 30 °C and 35 °C. In direct proportion to the module surface temperatures, 13 % better electrical efficiency was obtained in PV/T-VCRS 25 °C compared to 30 °C and 35 °C. The COP value increased by 15.46 % in PV/T-VCRS 25 °C compared to 30 °C and 35 °C. A 13 % improvement in exergy efficiency was observed in PV/T-VCRS 25 °C compared to 30 °C and 35 °C. The enviroeconomic parameter PV/T-VCRS is calculated as 15.17 ¢/h, 16.52 ¢/h, and 17.6 ¢/h for 25 °C, 30 °C and 35 °C. Another advantage of the system is that hot water is obtained at set temperatures. In PV/T-VCRS, 475 L, 300 L, and 210 L of hot water were obtained at 25 °C, 30 °C, and 35 °C, respectively. As a result, the performance of the PV/T-VCRS was good, with the added benefit of performing close to the performances when PV/T and VCRS were used separately.

HeliyonVol. 10(19)
California State University Los Angeles (US), Western Caspian University (AZ), Yıldız Technical University (TR), Düzce Üniversitesi (TR)
Openalex Percentile: Top 13%
Refrigeration and Air Conditioning Technologies
2.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.