Nonlinear vibrational spectrometer for bioapplications featuring narrowband 1-µm pulses and a recycled OPA pump beam

Moving the detection wavelength in vibrational sum-frequency generation (VSFG) spectroscopy to the near-infrared (> 700 nm) is crucial to avoid autofluorescence and electronic resonance effects distorting the molecular phase response or triggering unwanted chemical and photophysical reactions. Here, we employ an ultra-narrow bandpass interference filter on Yb laser pulses to generate an upconversion beam near 1.03 µm at a spectral resolution of 5 cm -1 . We demonstrate that the beam rejected by the filter can be utilized for driving a supercontinuum-seeded near-infrared optical parametric amplifier, boosting the seed energy for a broadband LiGaS 2 -based mid-infrared amplifier. Through the example of a chromoprotein, we show that utilizing the scheme can extend the range of interfacial molecular systems that can be studied using VSFG spectroscopy, even in the case of high repetition rate Yb pump lasers with limited pulse energy. The scheme can also be utilized in other types of vibrational spectroscopies that derive their spectral resolution from bandpass-filtering of femtosecond near-infrared laser pulses, such as stimulated Raman scattering (SRS) and coherent anti-Stokes Raman scattering (CARS) spectroscopy.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2024-09-10
DOI
https://doi.org/10.1364/oe.539940
Citations
3
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
1.99
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nonlinear vibrational spectrometer for bioapplications featuring narrowband 1-µm pulses and a recycled OPA pump beam

Zsuzsanna Heiner, Mark Mero, Valentin Petrov, András Dér
3 citations
Optics Express
Spectroscopy Techniques in Biomedical and Chemical Research
1.99
article

Nonlinear vibrational spectrometer for bioapplications featuring narrowband 1-µm pulses and a recycled OPA pump beam

Zsuzsanna Heiner, Mark Mero, Valentin Petrov, András Dér
article en
3 citations

Abstract

Moving the detection wavelength in vibrational sum-frequency generation (VSFG) spectroscopy to the near-infrared (> 700 nm) is crucial to avoid autofluorescence and electronic resonance effects distorting the molecular phase response or triggering unwanted chemical and photophysical reactions. Here, we employ an ultra-narrow bandpass interference filter on Yb laser pulses to generate an upconversion beam near 1.03 µm at a spectral resolution of 5 cm -1 . We demonstrate that the beam rejected by the filter can be utilized for driving a supercontinuum-seeded near-infrared optical parametric amplifier, boosting the seed energy for a broadband LiGaS 2 -based mid-infrared amplifier. Through the example of a chromoprotein, we show that utilizing the scheme can extend the range of interfacial molecular systems that can be studied using VSFG spectroscopy, even in the case of high repetition rate Yb pump lasers with limited pulse energy. The scheme can also be utilized in other types of vibrational spectroscopies that derive their spectral resolution from bandpass-filtering of femtosecond near-infrared laser pulses, such as stimulated Raman scattering (SRS) and coherent anti-Stokes Raman scattering (CARS) spectroscopy.

Optics ExpressVol. 32(25)
HUN-REN Szegedi Biológiai Kutatóközpont (HU), Humboldt-Universität zu Berlin (DE), Max-Born-Institute for Nonlinear Optics and Short Pulse Spectroscopy (DE)
Affordable and clean energy
Openalex Percentile: Top 12%
Spectroscopy Techniques in Biomedical and Chemical Research
1.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Nonlinear vibrational spectrometer for bioapplications featuring narrowband 1-µm pulses and a recycled OPA pump beam — Zsuzsanna Heiner, Mark Mero, et al. · Optics Express (2024) | TGRS Research Map | TGRS