Assessment of Surface Roughness, Color, and Bonding Efficacy: Self-Adhesive vs. Conventional Flowable Resin

This in vitro study aimed to analyze the surface roughness (Ra) and color stability (ΔEab, ΔE00) following simulated mechanical brushing and to evaluate the microtensile (μTBS) of self-adhering resin flowable (SARF) to dentin. The selected materials were Constic, Yflow AS, and Tetric N flow (TNF/control). Thirty composite resin cylinders were fabricated for surface property evaluation. Ra and color were assessed both before and after simulated brushing. The thresholds of 50:50% perceptibility and acceptability of color differences in the evaluated resins were assessed. For μTBS analysis, fifteen molars were selected, sectioned to expose flat dentin surfaces, and restored according to the manufacturers' instructions for microtensile testing. There were statistically significant differences in Ra among the groups, with Constic exhibiting the highest Ra value (0.702 µm; <i>p</i> < 0.05), whereas Yflow AS presented the lowest Ra value (0.184 µm). No statistically significant difference in color was observed among the groups (<i>p</i> > 0.05). The 50:50% perceptibility and acceptability thresholds were set at 1.2 and 2.7 for ΔEab and 0.8 and 1.8 for ΔE 00. All the results fell within the acceptable limits. The mean μTBS values of Constic, Yflow AS, and TNF were 10.649 MPa, 8.170 MPa, and 33.669 MPa, respectively. This study revealed increased Ra and comparable color stability among all the tested composite resins after abrasion. However, the SARF exhibited lower μTBS compared to conventional using an adhesive system.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2024-09-10
DOI
https://doi.org/10.3390/polym16182556
Citations
3
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Surface Roughness, Color, and Bonding Efficacy: Self-Adhesive vs. Conventional Flowable Resin

Cleyton Cézar Souto Silva, Ana Karina Maciel de Andrade, Caroline de Farias Charamba Leal, Samille Biasi Miranda et al.
3 citations
Polymers
Dental materials and restorations
1.21
article

Assessment of Surface Roughness, Color, and Bonding Efficacy: Self-Adhesive vs. Conventional Flowable Resin

Cleyton Cézar Souto Silva, Ana Karina Maciel de Andrade, Caroline de Farias Charamba Leal, Samille Biasi Miranda, André Ulisses Dantas Batista, Marcos Antônio Japiassú Resende Montes, Renally Bezerra Wanderley e Lima, Beatriz Barros Viana, Rodrigo Barros Esteves Lins
article en
3 citations

Abstract

This in vitro study aimed to analyze the surface roughness (Ra) and color stability (ΔEab, ΔE00) following simulated mechanical brushing and to evaluate the microtensile (μTBS) of self-adhering resin flowable (SARF) to dentin. The selected materials were Constic, Yflow AS, and Tetric N flow (TNF/control). Thirty composite resin cylinders were fabricated for surface property evaluation. Ra and color were assessed both before and after simulated brushing. The thresholds of 50:50% perceptibility and acceptability of color differences in the evaluated resins were assessed. For μTBS analysis, fifteen molars were selected, sectioned to expose flat dentin surfaces, and restored according to the manufacturers' instructions for microtensile testing. There were statistically significant differences in Ra among the groups, with Constic exhibiting the highest Ra value (0.702 µm; <i>p</i> < 0.05), whereas Yflow AS presented the lowest Ra value (0.184 µm). No statistically significant difference in color was observed among the groups (<i>p</i> > 0.05). The 50:50% perceptibility and acceptability thresholds were set at 1.2 and 2.7 for ΔEab and 0.8 and 1.8 for ΔE 00. All the results fell within the acceptable limits. The mean μTBS values of Constic, Yflow AS, and TNF were 10.649 MPa, 8.170 MPa, and 33.669 MPa, respectively. This study revealed increased Ra and comparable color stability among all the tested composite resins after abrasion. However, the SARF exhibited lower μTBS compared to conventional using an adhesive system.

PolymersVol. 16(18)
Universidade Federal da Paraíba (BR), Universidade de Pernambuco (BR), Universidade Federal de Alagoas (BR)
Openalex Percentile: Top 25%
Dental materials and restorations
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.