Effect of novel aluminium titanate on mechanical, thermal and ablation performance behavior of carbon fiber reinforced phenolic resin composites

Abstract Thermal Protection Systems (TPS) protect re‐entry space vehicles from the harsh heating they encounter when hypersonically flying through a planet or the earth's atmosphere. Carbon fiber‐reinforced phenolic resin composites were widely used for the thermal barrier structure of aerospace re‐entry vehicles. A Novel Aluminium Titanate (Al 2 TiO 5 /AT) micro powder‐modified Polyacrylonitrile (PAN) based Carbon Fiber Fabric‐Resorcinol Phenol Formaldehyde Resin (C‐PR) (AT‐C‐PR) composites are well prepared to meet the requirements of TPS. The AT may act as an insulating layer and anti‐ablative material due to its excellent thermal shock resistance in TPS. To understand the effectiveness of AT content on density, barcol hardness, interfacial interactions, thermal conductivity, and thermal stability, the C‐PR composites were produced with and without loading of AT with various weight percentages, namely 0 wt% (C‐PR), 1,3, and 5 wt% (AT‐C‐PR) by hot compression molding method. The microstructural and elemental change of the composites were analyzed by microscopic and spectroscopic studies. Results suggested that the Interlaminar Shear Strength (ILSS) of the composites was increased by about 14% at 1 wt% of AT loading. Mass, Linear Ablation Rates (MAR, LAR), and back‐face temperature of C‐PR and AT‐C‐PR composites were decreased to 0.15128 g/s, 0.01233 mm/s, and 405°C, respectively by loading of AT up to 1 wt%. The thermally ablated composites were also evaluated for their crystallographic phase changes. The work provided an effective way to improve the thermo‐mechanical and ablation performance characteristics of the AT‐C‐PR composites that can be potentially used in TPS of re‐entry vehicles. Highlights This investigation utilized innovative Al 2 TiO 5 /Aluminium Titanate (AT) ceramic powder as a filler in reinforcing Phenolic Resin (PR) with PAN‐based Carbon Fiber (C). It examined the impact of various loadings of AT in C‐PR composites (AT‐C‐PR) on their physical, mechanical, thermal, and anti‐ablation properties. The AT‐C‐PR composites exhibit reduced density, lower thermal conductivity, and enhanced ILSS (31 MPa) compared to the C‐PR composites. Optimal ablation resistance and thermal stability were achieved with a loading of 1 wt% AT (Mass Ablation Rate: 0.15128 g/s and Linear Ablation Rate: 0.01233 mm/s) compared to the C‐PR composites. Microstructural and elemental analysis of the composites were conducted using microscopy and energy‐dispersive spectroscopy, revealing the presence of oxides and carbides on the ablated surface. The phase transition and alterations in microstructure, coupled with the oxidation of AT, have enhanced the ablation resistance and reduced the back face temperature of different weight percentages of AT‐C‐PR composites, such as 1 wt% AT (413°C), compared to the C‐PR composites (704°C).

Authors

Institutions

Publication Details

Journal
Polymer Composites
Published
2024-09-10
DOI
https://doi.org/10.1002/pc.29046
Citations
9
Primary Topic
Tribology and Wear Analysis
Type
article
Field-Weighted Citation Impact
2.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of novel aluminium titanate on mechanical, thermal and ablation performance behavior of carbon fiber reinforced phenolic resin composites

Venkata Swamy Naidu Neigapula, Praveen Kumar Basingala
9 citations
Polymer Composites
Tribology and Wear Analysis
2.42
article

Effect of novel aluminium titanate on mechanical, thermal and ablation performance behavior of carbon fiber reinforced phenolic resin composites

Venkata Swamy Naidu Neigapula, Praveen Kumar Basingala
article en
9 citations

Abstract

Abstract Thermal Protection Systems (TPS) protect re‐entry space vehicles from the harsh heating they encounter when hypersonically flying through a planet or the earth's atmosphere. Carbon fiber‐reinforced phenolic resin composites were widely used for the thermal barrier structure of aerospace re‐entry vehicles. A Novel Aluminium Titanate (Al 2 TiO 5 /AT) micro powder‐modified Polyacrylonitrile (PAN) based Carbon Fiber Fabric‐Resorcinol Phenol Formaldehyde Resin (C‐PR) (AT‐C‐PR) composites are well prepared to meet the requirements of TPS. The AT may act as an insulating layer and anti‐ablative material due to its excellent thermal shock resistance in TPS. To understand the effectiveness of AT content on density, barcol hardness, interfacial interactions, thermal conductivity, and thermal stability, the C‐PR composites were produced with and without loading of AT with various weight percentages, namely 0 wt% (C‐PR), 1,3, and 5 wt% (AT‐C‐PR) by hot compression molding method. The microstructural and elemental change of the composites were analyzed by microscopic and spectroscopic studies. Results suggested that the Interlaminar Shear Strength (ILSS) of the composites was increased by about 14% at 1 wt% of AT loading. Mass, Linear Ablation Rates (MAR, LAR), and back‐face temperature of C‐PR and AT‐C‐PR composites were decreased to 0.15128 g/s, 0.01233 mm/s, and 405°C, respectively by loading of AT up to 1 wt%. The thermally ablated composites were also evaluated for their crystallographic phase changes. The work provided an effective way to improve the thermo‐mechanical and ablation performance characteristics of the AT‐C‐PR composites that can be potentially used in TPS of re‐entry vehicles. Highlights This investigation utilized innovative Al 2 TiO 5 /Aluminium Titanate (AT) ceramic powder as a filler in reinforcing Phenolic Resin (PR) with PAN‐based Carbon Fiber (C). It examined the impact of various loadings of AT in C‐PR composites (AT‐C‐PR) on their physical, mechanical, thermal, and anti‐ablation properties. The AT‐C‐PR composites exhibit reduced density, lower thermal conductivity, and enhanced ILSS (31 MPa) compared to the C‐PR composites. Optimal ablation resistance and thermal stability were achieved with a loading of 1 wt% AT (Mass Ablation Rate: 0.15128 g/s and Linear Ablation Rate: 0.01233 mm/s) compared to the C‐PR composites. Microstructural and elemental analysis of the composites were conducted using microscopy and energy‐dispersive spectroscopy, revealing the presence of oxides and carbides on the ablated surface. The phase transition and alterations in microstructure, coupled with the oxidation of AT, have enhanced the ablation resistance and reduced the back face temperature of different weight percentages of AT‐C‐PR composites, such as 1 wt% AT (413°C), compared to the C‐PR composites (704°C).

Polymer CompositesVol. 46(2)
National Institute of Technology Raipur (IN)
Openalex Percentile: Top 12%
Tribology and Wear Analysis
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.