CHARACTERISTICS OF RESONANT SYSTEMS FOR OBTAINING HIGH VOLTAGE ON A CAPACITIVE LOAD

The work is devoted to the comparative analysis of currents in inverter circuits of transformerless resonant and transformer resonant and non-resonant systems of the same power for obtaining high voltage on a capacitive load. The purpose of the work is to determine the type of system characterized by the smallest average operating current of the inverter switches. The dependence of the currents in the circuits of the inverters on the parameters of the resonant circuits was obtained, the results of calculations according to which allow us to state that the use of a transformerless circuit to ensure the same power of systems for obtaining high voltage on a capacitive type load will allow to almost halve the average operating current in the inverter circuit. Simulation modeling of the processes in the studied schemes was carried out, which confirms the obtained theoretical results. The use of high-voltage transformerless resonant systems to obtain high voltage on a capacitive load will allow to halve the nominal and maximum permissible current characteristics of the power elements of the converters. Ref. 10, fig. 3.

Authors

Publication Details

Journal
Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
Published
2024-08-30
DOI
https://doi.org/10.15407/publishing2024.68.087
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CHARACTERISTICS OF RESONANT SYSTEMS FOR OBTAINING HIGH VOLTAGE ON A CAPACITIVE LOAD

Dmytro Vinnychenko
Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
Electric Power Systems and Control
article

CHARACTERISTICS OF RESONANT SYSTEMS FOR OBTAINING HIGH VOLTAGE ON A CAPACITIVE LOAD

Dmytro Vinnychenko
article en

Abstract

The work is devoted to the comparative analysis of currents in inverter circuits of transformerless resonant and transformer resonant and non-resonant systems of the same power for obtaining high voltage on a capacitive load. The purpose of the work is to determine the type of system characterized by the smallest average operating current of the inverter switches. The dependence of the currents in the circuits of the inverters on the parameters of the resonant circuits was obtained, the results of calculations according to which allow us to state that the use of a transformerless circuit to ensure the same power of systems for obtaining high voltage on a capacitive type load will allow to almost halve the average operating current in the inverter circuit. Simulation modeling of the processes in the studied schemes was carried out, which confirms the obtained theoretical results. The use of high-voltage transformerless resonant systems to obtain high voltage on a capacitive load will allow to halve the nominal and maximum permissible current characteristics of the power elements of the converters. Ref. 10, fig. 3.

Praci Institutu elektrodinamiki Nacionalanoi akademii nauk UkrainiVol. 2024(68)
Affordable and clean energy
Openalex Percentile: Top 87%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

CHARACTERISTICS OF RESONANT SYSTEMS FOR OBTAINING HIGH VOLTAGE ON A CAPACITIVE LOAD — Dmytro Vinnychenko · Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini (2024) | TGRS Research Map | TGRS