Cough Induced Rib Fracture in Pregnant Patient: Role of Ultrasound

Dear Editor, Cough induced rib fractures during pregnancy are rare and pose unique diagnostic challenges due to the need for minimizing fetal radiation exposure. We present a case of 30 years old pregnant woman in her third trimester who experienced acute chest pain following a severe cough episode. Due to potential risks associated with radiographic imaging, a chest ultrasound was utilized, effectively identifying a fracture in the right 10th rib. This case underscores the critical role of ultrasound in safely and accurately diagnosing rib fractures in pregnant patients, offering a reliable and radiation-free alternative to traditional imaging methods. A 30-year-old female patient who was 27 weeks pregnant presented with acute chest pain following a severe cough episode. She has no known disease and no abnormal findings were found during routine checks during her pregnancy. The examination revealed no findings other than tenderness in the right upper quadrant. An increase in WBC (11.83 10^3/uL) and CRP (22 mg/L) values was detected in laboratory tests. Laboratory values were thought to be due to upper respiratory tract infection and ultrasonography was performed for right upper quadrant pain. Liver echogenicity and size, gallbladder and right kidney were evaluated as normal in abdominal ultrasonography. In the examination performed with superficial probe on the local area where pain was described, discontinuity and stepping signs were observed in the outer contour of the right 10th rib (Figure 1). It was determined that the patient’s pain increased when light pressure was applied with the probe to the location where these findings were found. As a result of the examination and ultrasonography findings, a diagnosis of rib fracture was made. No hematoma or space-occupying lesion was detected in the surrounding tissues. No signs of fracture were detected by ultrasonography in the 9th and 11th ribs or the other ribs. Medical treatment was given to the patient who had a single rib fracture and no examination or ultrasonography findings suggestive of pneumothorax.

Authors

Institutions

Publication Details

Journal
European Journal of Therapeutics
Published
2024-09-10
DOI
https://doi.org/10.58600/eurjther2293
Citations
1
Primary Topic
Trauma Management and Diagnosis
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cough Induced Rib Fracture in Pregnant Patient: Role of Ultrasound

Cemre Özenbaş, Hakan Koca
1 citations
European Journal of Therapeutics
Trauma Management and Diagnosis
0.57
article

Cough Induced Rib Fracture in Pregnant Patient: Role of Ultrasound

Cemre Özenbaş, Hakan Koca
article en
1 citations

Abstract

Dear Editor, Cough induced rib fractures during pregnancy are rare and pose unique diagnostic challenges due to the need for minimizing fetal radiation exposure. We present a case of 30 years old pregnant woman in her third trimester who experienced acute chest pain following a severe cough episode. Due to potential risks associated with radiographic imaging, a chest ultrasound was utilized, effectively identifying a fracture in the right 10th rib. This case underscores the critical role of ultrasound in safely and accurately diagnosing rib fractures in pregnant patients, offering a reliable and radiation-free alternative to traditional imaging methods. A 30-year-old female patient who was 27 weeks pregnant presented with acute chest pain following a severe cough episode. She has no known disease and no abnormal findings were found during routine checks during her pregnancy. The examination revealed no findings other than tenderness in the right upper quadrant. An increase in WBC (11.83 10^3/uL) and CRP (22 mg/L) values was detected in laboratory tests. Laboratory values were thought to be due to upper respiratory tract infection and ultrasonography was performed for right upper quadrant pain. Liver echogenicity and size, gallbladder and right kidney were evaluated as normal in abdominal ultrasonography. In the examination performed with superficial probe on the local area where pain was described, discontinuity and stepping signs were observed in the outer contour of the right 10th rib (Figure 1). It was determined that the patient’s pain increased when light pressure was applied with the probe to the location where these findings were found. As a result of the examination and ultrasonography findings, a diagnosis of rib fracture was made. No hematoma or space-occupying lesion was detected in the surrounding tissues. No signs of fracture were detected by ultrasonography in the 9th and 11th ribs or the other ribs. Medical treatment was given to the patient who had a single rib fracture and no examination or ultrasonography findings suggestive of pneumothorax.

European Journal of TherapeuticsVol. 30(6)
Izmir University (TR)
Zero hunger
Openalex Percentile: Top 30%
Trauma Management and Diagnosis
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.