A One-Dimensional Computational Model to Identify Operating Conditions and Cathode Flow Channel Dimensions for a Proton Exchange Membrane Fuel Cell

A one-dimensional computational model has been developed that can be used to identify operating conditions for the cathode side of a proton exchange membrane fuel cell such that both the inlet and outlet relative humidity is equal to 100%. By balancing the calculated pressure drop along the cathode side flow channel with the change in molar composition, inlet conditions for the cathode side can be identified with the goal of avoiding channel flooding. The channel length, height, width and the land-to-channel width ratio are input parameters for the model so that it might be used to dimension the cathode flow field. The model can be used to calculate the limiting current density, and we are presenting unprecedented high values as a result of the high pressure drop along the flow channels. Such high current densities can ultimately result in a fuel cell power density beyond the typical value of 1.0–2.0 W/cm2 for automotive fuel cells.

Authors

Institutions

Publication Details

Journal
Hydrogen
Published
2024-09-10
DOI
https://doi.org/10.3390/hydrogen5030033
Citations
4
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A One-Dimensional Computational Model to Identify Operating Conditions and Cathode Flow Channel Dimensions for a Proton Exchange Membrane Fuel Cell

Torsten Berning, Nikolaj M. Bielefeld, Rasmus D. Sørensen, Mikkel Jørgensen et al.
4 citations
Hydrogen
Fuel Cells and Related Materials
0.83
article

A One-Dimensional Computational Model to Identify Operating Conditions and Cathode Flow Channel Dimensions for a Proton Exchange Membrane Fuel Cell

Torsten Berning, Nikolaj M. Bielefeld, Rasmus D. Sørensen, Mikkel Jørgensen, Kristoffer S. Kure
article en
4 citations

Abstract

A one-dimensional computational model has been developed that can be used to identify operating conditions for the cathode side of a proton exchange membrane fuel cell such that both the inlet and outlet relative humidity is equal to 100%. By balancing the calculated pressure drop along the cathode side flow channel with the change in molar composition, inlet conditions for the cathode side can be identified with the goal of avoiding channel flooding. The channel length, height, width and the land-to-channel width ratio are input parameters for the model so that it might be used to dimension the cathode flow field. The model can be used to calculate the limiting current density, and we are presenting unprecedented high values as a result of the high pressure drop along the flow channels. Such high current densities can ultimately result in a fuel cell power density beyond the typical value of 1.0–2.0 W/cm2 for automotive fuel cells.

HydrogenVol. 5(3)
Aalborg University (DK)
Openalex Percentile: Top 27%
Fuel Cells and Related Materials
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.