Comparing Abdominal and Retroperitoneal Organ Sonographic Measurements to Postdissection Measurements: A Pilot Study

Objective: Variation in organ size can occur due to different sonographic scan planes used to make measurements. Diagnostic accuracy may be compromised due to the variations in organ measurement. Therefore, the aim of this study was to compare sonographic measurements and actual organ measurements, taken predissection and postdissection, to determine the accuracy of sonographic measurements, taken in various sonographic scan planes. Materials and Methods: Sonographic organ measurements were made of the liver, kidney, and spleen, prior to cadaver dissection. Liver length measurements were acquired in the midclavicular and intercostal sonographic scan planes. All kidney length, height, and width measurements were acquired scanning from the anterior and coronal planes. Spleen measurements were acquired using an intercostal sonographic scan plane, using longest dimension for length, and acquiring transverse measurements from both a 90-degree and a 180-degree transducer rotation. Descriptive statistics were reported using mean, standard deviation, median, and interquartile range. Results: Liver length, spleen length, right kidney length and width, and left kidney width showed no measurement differences. Sonographic measurements of right kidney height varied ( p < .0001). The sonographic left kidney length was more accurate when acquired in the coronal plane ( p = .006), and the height measurement was more accurate taken from the anterior plane ( p < .001). Spleen width varied between the 90-degree and 180-degree transducer rotation, and postdissection measures ( p = .0010). Conclusion: This pilot study would suggest that there is a need for the development of standardized sonographic organ measurement protocols.

Authors

Institutions

Publication Details

Journal
Journal of diagnostic medical sonography
Published
2024-09-09
DOI
https://doi.org/10.1177/87564793241278998
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing Abdominal and Retroperitoneal Organ Sonographic Measurements to Postdissection Measurements: A Pilot Study

Jennifer Bagley, MacKay Whalen, Jonathan D. Baldwin
Journal of diagnostic medical sonography
Radiation Dose and Imaging
article

Comparing Abdominal and Retroperitoneal Organ Sonographic Measurements to Postdissection Measurements: A Pilot Study

Jennifer Bagley, MacKay Whalen, Jonathan D. Baldwin
article en

Abstract

Objective: Variation in organ size can occur due to different sonographic scan planes used to make measurements. Diagnostic accuracy may be compromised due to the variations in organ measurement. Therefore, the aim of this study was to compare sonographic measurements and actual organ measurements, taken predissection and postdissection, to determine the accuracy of sonographic measurements, taken in various sonographic scan planes. Materials and Methods: Sonographic organ measurements were made of the liver, kidney, and spleen, prior to cadaver dissection. Liver length measurements were acquired in the midclavicular and intercostal sonographic scan planes. All kidney length, height, and width measurements were acquired scanning from the anterior and coronal planes. Spleen measurements were acquired using an intercostal sonographic scan plane, using longest dimension for length, and acquiring transverse measurements from both a 90-degree and a 180-degree transducer rotation. Descriptive statistics were reported using mean, standard deviation, median, and interquartile range. Results: Liver length, spleen length, right kidney length and width, and left kidney width showed no measurement differences. Sonographic measurements of right kidney height varied ( p < .0001). The sonographic left kidney length was more accurate when acquired in the coronal plane ( p = .006), and the height measurement was more accurate taken from the anterior plane ( p < .001). Spleen width varied between the 90-degree and 180-degree transducer rotation, and postdissection measures ( p = .0010). Conclusion: This pilot study would suggest that there is a need for the development of standardized sonographic organ measurement protocols.

Journal of diagnostic medical sonographyVol. 41(2)
Norman Regional Hospital (US), University of Oklahoma Health Sciences Center (US)
Openalex Percentile: Top 75%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.