Long-term outcomes of acetabular impaction grafting with cemented cups and trabecular metal for revision hip arthroplasty: a follow-up study
AIBG demonstrated high failure rates at long-term follow-up when compared to TM constructs. We recommend the use of AIBG in small cavitary defects only. We strongly advise against its use in the setting of significant bony defects and for prosthetic joint infection.
Authors
- Fiachra Rowan (ORCID: https://orcid.org/0000-0003-1190-0349)
- Shane Irwin (ORCID: https://orcid.org/0000-0001-6303-0280)
- Rayyan S. Mirdad (ORCID: https://orcid.org/0000-0003-3951-9259)
- Shane P. Russell (ORCID: https://orcid.org/0000-0002-7305-8479)
- Mark Curtin (ORCID: https://orcid.org/0000-0002-6191-1508)
- Eric Masterson
- Finbarr Condon
Institutions
- Royal College of Surgeons in Ireland (IE)
- University Hospital Limerick (IE)
Publication Details
- Journal
- Hip International
- Published
- 2024-09-09
- DOI
- https://doi.org/10.1177/11207000241266939
- Citations
- 3
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 1.72