Oily Wastewater Treatment by Using Fe3O4/Bentonite in Fixed-Bed Adsorption Column

Oily wastewater is a major environmental issue resulting from different industrial and manufacturing activities. Contaminated water with oil represents a significant environmental hazard that can harm numerous life forms. Several methodologies have been tested for the removal of oily wastewater from aqueous solutions, and adsorption in a flow-through reactor is an effective mechanism to reduce these effluents. This study focuses on evaluating the ability of Fe3O4/Bent material to adsorb gasoline emulsion from a solution using a fixed-bed column, and it involves analyzing the resulting breakthrough curves. The FT-IR, SEM, EDX, and XRD techniques were used to characterize Fe3O4/Bent. Various ranges of variables were examined, including bed height (2–4 cm), flow rate (3–3.8 mL/min), and initial concentration (200–1000 mg/L), to determine their impacts on the mass transfer zone (MTZ) length and the adsorption capacity (qe). It was shown that a higher bed height and a lower flow rate contributed to a longer time of breakthrough and exhaustion. At the same time, it was noted that under high initial gasoline concentrations, the fixed-bed system rapidly reached breakthrough and exhaustion. Models like the Yoon–Nelson and Thomas kinetic column models were employed to predict the breakthrough curves. Thomas and Yoon–Nelson’s breakthrough models provided a good fit for the breakthrough curves with a correlation coefficient of R2 > 0.95. Furthermore, with a fixed-bed system, the Thomas and Yoon–Nelson models best describe the breakthrough curves for gasoline removal.

Authors

Institutions

Publication Details

Journal
ChemEngineering
Published
2024-09-10
DOI
https://doi.org/10.3390/chemengineering8050092
Citations
11
Primary Topic
Adsorption and biosorption for pollutant removal
Type
article
Field-Weighted Citation Impact
2.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Oily Wastewater Treatment by Using Fe3O4/Bentonite in Fixed-Bed Adsorption Column

Alaa Dhari Jawad Al-Bayati, Mohammed Alktranee, Mohammed F. Abid, Khalid T. Rashid et al.
11 citations
ChemEngineering
Adsorption and biosorption for pollutant removal
2.22
article

Oily Wastewater Treatment by Using Fe3O4/Bentonite in Fixed-Bed Adsorption Column

Alaa Dhari Jawad Al-Bayati, Mohammed Alktranee, Mohammed F. Abid, Khalid T. Rashid, Adnan A. AbdulRazak, Haidar Hasan Mohammed, Mohammed Ahmed Shehab, Mohammed A. Sarran, Saad Alsarayefi, Mahmood Alhafadhi
article en
11 citations

Abstract

Oily wastewater is a major environmental issue resulting from different industrial and manufacturing activities. Contaminated water with oil represents a significant environmental hazard that can harm numerous life forms. Several methodologies have been tested for the removal of oily wastewater from aqueous solutions, and adsorption in a flow-through reactor is an effective mechanism to reduce these effluents. This study focuses on evaluating the ability of Fe3O4/Bent material to adsorb gasoline emulsion from a solution using a fixed-bed column, and it involves analyzing the resulting breakthrough curves. The FT-IR, SEM, EDX, and XRD techniques were used to characterize Fe3O4/Bent. Various ranges of variables were examined, including bed height (2–4 cm), flow rate (3–3.8 mL/min), and initial concentration (200–1000 mg/L), to determine their impacts on the mass transfer zone (MTZ) length and the adsorption capacity (qe). It was shown that a higher bed height and a lower flow rate contributed to a longer time of breakthrough and exhaustion. At the same time, it was noted that under high initial gasoline concentrations, the fixed-bed system rapidly reached breakthrough and exhaustion. Models like the Yoon–Nelson and Thomas kinetic column models were employed to predict the breakthrough curves. Thomas and Yoon–Nelson’s breakthrough models provided a good fit for the breakthrough curves with a correlation coefficient of R2 > 0.95. Furthermore, with a fixed-bed system, the Thomas and Yoon–Nelson models best describe the breakthrough curves for gasoline removal.

ChemEngineeringVol. 8(5)
University of Basrah (IQ), University of Mons (BE), University of Technology - Iraq (IQ), University of Miskolc (HU), Thi Qar University (IQ), Al-Turath University (IQ), Alsalam University College (IQ), Southern Technical University (IQ), Al-Mustaqbal University
Clean water and sanitation
Openalex Percentile: Top 13%
Adsorption and biosorption for pollutant removal
2.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.