The Use of Low‐Quality Cotton‐Derived Cellulose Films as Templates for In Situ Conductive Polymer Synthesis as Promising Biomaterials in Biomedical Applications

Abstract Here, the use of cellulose films (CFs) produced from low‐quality cotton is reported as a template for in situ synthesis of well‐known conductive polymers, e.g., polyaniline (PANI) and polypyrrole (PPY) via oxidative polymerization. Three successive monomer loading/polymerization cycles of aniline (ANI) and pyrrole (PY) within CFs as PANI@CF or PPY@CF are carried out to increase the amount of conductive polymer content. The contact angle (CA) for three times ANI and PPY loaded and polymerized CFs as 3PANI@CF and 3PPY@CF are determined as 26.3±2.8 and 42.3±0.6 degrees, respectively. As the electrical conductivity is increased with increased number of conductive polymer synthesis within CF, the higher conductivity values, 3×10 −4 ±8.1×10 −5 S.cm −1 and 2.1×10 −3 ±5.8×10 −4 S.cm −1 , respectively are measured for 3PANI@CF and 3PPY@CF composites. It is found that PANI@CF composites are hemolytic, whereas PPY@CF composites are not at 1 mg mL −1 concentrations. All PPY@CF composites exhibit better biocompatibility than PANI@CF composites on L929 fibroblast cells with more than 70±8% viability at 1 mg of CF‐based conductive polymer composites. Moreover, MIC and MBC values of 3PPY@CF composites for Escherichia coli (ATCC8739) and Staphylococcus aureus (ATCC6538) are determined as 2.5 and 5.0 mg.mL −1 , whereas these values are estimated as 5 and 10 mg.mL −1 for Candida albicans (ATCC10231).

Authors

Institutions

Publication Details

Journal
Macromolecular Materials and Engineering
Published
2024-09-10
DOI
https://doi.org/10.1002/mame.202400246
Citations
2
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
0.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Use of Low‐Quality Cotton‐Derived Cellulose Films as Templates for In Situ Conductive Polymer Synthesis as Promising Biomaterials in Biomedical Applications

Nurettin Şahiner, Selin Sagbas, Mehtap Sahiner, Shaida S. Rumi et al.
2 citations
Macromolecular Materials and Engineering
Conducting polymers and applications
0.34
article

The Use of Low‐Quality Cotton‐Derived Cellulose Films as Templates for In Situ Conductive Polymer Synthesis as Promising Biomaterials in Biomedical Applications

Nurettin Şahiner, Selin Sagbas, Mehtap Sahiner, Shaida S. Rumi, Şahin Demirci, Noureddine Abidi
article en
2 citations

Abstract

Abstract Here, the use of cellulose films (CFs) produced from low‐quality cotton is reported as a template for in situ synthesis of well‐known conductive polymers, e.g., polyaniline (PANI) and polypyrrole (PPY) via oxidative polymerization. Three successive monomer loading/polymerization cycles of aniline (ANI) and pyrrole (PY) within CFs as PANI@CF or PPY@CF are carried out to increase the amount of conductive polymer content. The contact angle (CA) for three times ANI and PPY loaded and polymerized CFs as 3PANI@CF and 3PPY@CF are determined as 26.3±2.8 and 42.3±0.6 degrees, respectively. As the electrical conductivity is increased with increased number of conductive polymer synthesis within CF, the higher conductivity values, 3×10 −4 ±8.1×10 −5 S.cm −1 and 2.1×10 −3 ±5.8×10 −4 S.cm −1 , respectively are measured for 3PANI@CF and 3PPY@CF composites. It is found that PANI@CF composites are hemolytic, whereas PPY@CF composites are not at 1 mg mL −1 concentrations. All PPY@CF composites exhibit better biocompatibility than PANI@CF composites on L929 fibroblast cells with more than 70±8% viability at 1 mg of CF‐based conductive polymer composites. Moreover, MIC and MBC values of 3PPY@CF composites for Escherichia coli (ATCC8739) and Staphylococcus aureus (ATCC6538) are determined as 2.5 and 5.0 mg.mL −1 , whereas these values are estimated as 5 and 10 mg.mL −1 for Candida albicans (ATCC10231).

Macromolecular Materials and EngineeringVol. 310(1)
Çanakkale Onsekiz Mart Üniversitesi (TR), Texas Tech University (US), University of South Florida (US), Florida Gulf Coast University (US)
University of South Florida
Openalex Percentile: Top 50%
Conducting polymers and applications
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.