A Case Report About Cardiac Arrest After Left Ventricular Assist Device Explantation
Hemodynamic unloading by left ventricular assist devices (LVADs) in patients with advanced heart failure can result in reverse remodeling and cardiac recovery allowing pump removal. Ventriculoplasty during explantation may cause fibrosis and ventricular scars which can provide a substrate for reentry, a common cause of ventricular arrythmias. In this case report, we describe the clinical course of a patient who suffered a cardiac arrest in the following few months after undergoing LVAD explantation because of cardiac recovery. This case highlights a potential risk related to complete LVAD explantation with ventriculoplasty and patch repair of the apex.
Authors
- Ann Hallberg Kristensen
- Magnus Dalén (ORCID: https://orcid.org/0000-0001-5352-5132)
- Emil Najjar (ORCID: https://orcid.org/0000-0001-8066-2423)
- Tonje Thorvaldsen
- Edisson Nemer
- R. Rassam
Institutions
- Karolinska University Hospital (SE)
- Karolinska Institutet (SE)
Publication Details
- Journal
- ASAIO Journal
- Published
- 2024-09-10
- DOI
- https://doi.org/10.1097/mat.0000000000002304
- Citations
- 1
- Primary Topic
- Cardiac Structural Anomalies and Repair
- Type
- article
- Field-Weighted Citation Impact
- 0.57