Aortic Dissection in a Neonate Receiving Extracorporeal Life Support Therapy: A Case Report

Extracorporeal life support (ECLS) therapy is increasingly being used to support children with refractory cardiorespiratory failure, but its use is occasionally associated with complications. 1 Neonatal aortic dissection in association with ECLS is rare and the clinical sequelae of aortic dissection in neonates are poorly understood. We report a case of extensive type B aortic dissection in a neonate receiving ECLS therapy for refractory cardiogenic shock secondary to tachycardia-induced cardiomyopathy and Wolf Parkinson White (WPW) syndrome. The patient was noted to have aortic dissection along with multiple abdominal organ ischemic injury a day after ECLS arterial cannula position adjustment. The patient was rapidly decannulated from ECLS and the aortic dissection was managed conservatively with good outcome. We discuss our approach and rationale behind conservative management of this rarely reported complication associated with ECLS therapy and discuss available literature.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2024-09-10
DOI
https://doi.org/10.1097/mat.0000000000002306
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aortic Dissection in a Neonate Receiving Extracorporeal Life Support Therapy: A Case Report

Keith A. Kuenzler, Jason C. Fisher, Arun Chopra, Jaclyn McKinstry et al.
1 links
ASAIO Journal
Aortic Disease and Treatment Approaches
article

Aortic Dissection in a Neonate Receiving Extracorporeal Life Support Therapy: A Case Report

Keith A. Kuenzler, Jason C. Fisher, Arun Chopra, Jaclyn McKinstry, Shivanand Medar, Sujata Chakravarti, T. K. Susheel Kumar
article en

Abstract

Extracorporeal life support (ECLS) therapy is increasingly being used to support children with refractory cardiorespiratory failure, but its use is occasionally associated with complications. 1 Neonatal aortic dissection in association with ECLS is rare and the clinical sequelae of aortic dissection in neonates are poorly understood. We report a case of extensive type B aortic dissection in a neonate receiving ECLS therapy for refractory cardiogenic shock secondary to tachycardia-induced cardiomyopathy and Wolf Parkinson White (WPW) syndrome. The patient was noted to have aortic dissection along with multiple abdominal organ ischemic injury a day after ECLS arterial cannula position adjustment. The patient was rapidly decannulated from ECLS and the aortic dissection was managed conservatively with good outcome. We discuss our approach and rationale behind conservative management of this rarely reported complication associated with ECLS therapy and discuss available literature.

ASAIO JournalVol. 71(10)
New York University (US)
Responsible consumption and production
Openalex Percentile: Top 73%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.