Prior-Knowledge Embedded U-Net-Based Fully Automatic Vessel Wall Volume Measurement of the Carotid Artery in 3D Ultrasound Image

The vessel-wall-volume (VWV) measured based on three-dimensional (3D) carotid artery (CA) ultrasound (US) images can help to assess carotid atherosclerosis and manage patients at risk for stroke. Manual involvement for measurement work is subjective and requires well-trained operators, and fully automatic measurement tools are not yet available. Thereby, we proposed a fully automatic VWV measurement framework (Auto-VWV) using a CA prior-knowledge embedded U-Net (CAP-UNet) to measure the VWV from 3D CA US images without manual intervention. The Auto-VWV framework is designed to improve the repeated VWV measuring consistency, which resulted in the first fully automatic framework for VWV measurement. CAP-UNet is developed to improve segmentation accuracy on the whole CA, which composed of a U-Net type backbone and three additional prior-knowledge learning modules. Specifically, a continuity learning module is used to learn the spatial continuity of the arteries in a sequence of image slices. A voxel evolution learning module was designed to learn the evolution of the artery in adjacent slices, and a topology learning module was used to learn the unique topology of the carotid artery. In two 3D CA US datasets, CAP-UNet architecture achieved state-of-the-art performance compared to eight competing models. Furthermore, CAP-UNet-based Auto-VWV achieved better accuracy and consistency than Auto-VWV based on competing models in the simulated repeated measurement. Finally, using 10 pairs of real repeatedly scanned samples, Auto-VWV achieved better VWV measurement reproducibility than intra- and inter-operator manual measurements. The code is available at https://github.com/Yue9603/Auto-VWV.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Imaging
Published
2024-09-10
DOI
https://doi.org/10.1109/tmi.2024.3457245
Citations
1
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prior-Knowledge Embedded U-Net-Based Fully Automatic Vessel Wall Volume Measurement of the Carotid Artery in 3D Ultrasound Image

Aaron Fenster, Wenguang W. Hou, J. David Spence, Wu Qiu et al.
1 citations
IEEE Transactions on Medical Imaging
Cardiovascular Health and Disease Prevention
0.40
article

Prior-Knowledge Embedded U-Net-Based Fully Automatic Vessel Wall Volume Measurement of the Carotid Artery in 3D Ultrasound Image

Aaron Fenster, Wenguang W. Hou, J. David Spence, Wu Qiu, Mingyue Ding, Quan Zhou, Jiayao Jiang, Yue Zheng
article en
1 citations

Abstract

The vessel-wall-volume (VWV) measured based on three-dimensional (3D) carotid artery (CA) ultrasound (US) images can help to assess carotid atherosclerosis and manage patients at risk for stroke. Manual involvement for measurement work is subjective and requires well-trained operators, and fully automatic measurement tools are not yet available. Thereby, we proposed a fully automatic VWV measurement framework (Auto-VWV) using a CA prior-knowledge embedded U-Net (CAP-UNet) to measure the VWV from 3D CA US images without manual intervention. The Auto-VWV framework is designed to improve the repeated VWV measuring consistency, which resulted in the first fully automatic framework for VWV measurement. CAP-UNet is developed to improve segmentation accuracy on the whole CA, which composed of a U-Net type backbone and three additional prior-knowledge learning modules. Specifically, a continuity learning module is used to learn the spatial continuity of the arteries in a sequence of image slices. A voxel evolution learning module was designed to learn the evolution of the artery in adjacent slices, and a topology learning module was used to learn the unique topology of the carotid artery. In two 3D CA US datasets, CAP-UNet architecture achieved state-of-the-art performance compared to eight competing models. Furthermore, CAP-UNet-based Auto-VWV achieved better accuracy and consistency than Auto-VWV based on competing models in the simulated repeated measurement. Finally, using 10 pairs of real repeatedly scanned samples, Auto-VWV achieved better VWV measurement reproducibility than intra- and inter-operator manual measurements. The code is available at https://github.com/Yue9603/Auto-VWV.

IEEE Transactions on Medical ImagingVol. 44(2)
Western University (CA), Thrombosis and Atherosclerosis Research Institute (CA), Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 33%
Cardiovascular Health and Disease Prevention
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.