Spectral-feature anisotropy-based spectral CT reconstruction

The narrow energy bins of PCD-CT (Photon Counting Detector based Computed Tomography) make it hard to sufficiently collect incident photons. CT is performed at routine dose when dose constraint is met since relatively high doses of X-ray raise concerns about radiation risks. The above two points may both result in a Low-SNR (Low Signal-to-Noise Ratio) situation of projection data, leading noisy results. Besides, the SFA (spectral-feature anisotropy) exists in images corresponding different energy channels, it reflects the pixel saliency and spatial consistency of images related to different energy channels. The compatibility between mechanism of guided filter and the SFA prompted us to proposed a spectral CT reconstruction approach synergizing with both ADGF (Anisotropic Diffusion Guided Filter) and DAI (Dynamic Average Image) to reconstruct satisfying spectral CT image. ADGF was realized by fusing guided filter and anisotropic filter and was incorporated into the iterative process as a regularizer, making it more powerful in noise suppression while maintaining features. To further make full use of redundant information among different energy channels, DAI was utilized to induce channel-wise reconstruction. Experiments show that compared with results of other methods, ours achieve decent performance in visualization and quantitative indexes.

Authors

Institutions

Publication Details

Published
2024-09-10
DOI
https://doi.org/10.1117/12.3041170
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectral-feature anisotropy-based spectral CT reconstruction

Zhaojun Yang, Li Zeng
Advanced X-ray and CT Imaging
article

Spectral-feature anisotropy-based spectral CT reconstruction

Zhaojun Yang, Li Zeng
article en

Abstract

The narrow energy bins of PCD-CT (Photon Counting Detector based Computed Tomography) make it hard to sufficiently collect incident photons. CT is performed at routine dose when dose constraint is met since relatively high doses of X-ray raise concerns about radiation risks. The above two points may both result in a Low-SNR (Low Signal-to-Noise Ratio) situation of projection data, leading noisy results. Besides, the SFA (spectral-feature anisotropy) exists in images corresponding different energy channels, it reflects the pixel saliency and spatial consistency of images related to different energy channels. The compatibility between mechanism of guided filter and the SFA prompted us to proposed a spectral CT reconstruction approach synergizing with both ADGF (Anisotropic Diffusion Guided Filter) and DAI (Dynamic Average Image) to reconstruct satisfying spectral CT image. ADGF was realized by fusing guided filter and anisotropic filter and was incorporated into the iterative process as a regularizer, making it more powerful in noise suppression while maintaining features. To further make full use of redundant information among different energy channels, DAI was utilized to induce channel-wise reconstruction. Experiments show that compared with results of other methods, ours achieve decent performance in visualization and quantitative indexes.

Chongqing University (CN)
Climate action
Openalex Percentile: Top 86%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Spectral-feature anisotropy-based spectral CT reconstruction — Zhaojun Yang, Li Zeng · (2024) | TGRS Research Map | TGRS