Dual-Purpose Aptamer-Based Sensors for Real-Time, Multiplexable Monitoring of Metabolites in Cell Culture Media
The availability of high-frequency, real-time measurements of the concentrations of specific metabolites in cell culture systems will enable a deeper understanding of cellular metabolism and facilitate the application of good laboratory practice standards in cell culture protocols. However, currently available approaches to this end either are constrained to single-time-point and single-parameter measurements or are limited in the range of detectable analytes. Electrochemical aptamer-based (EAB) biosensors have demonstrated utility in real-time monitoring of analytes <i>in vivo</i> in blood and tissues. Here, we characterize a pH-sensing capability of EAB sensors that is independent of the specific target analyte of the aptamer sequence. We applied this dual-purpose EAB to the continuous measurement of pH and phenylalanine in several <i>in vitro</i> cell culture settings. The miniature EAB sensor that we developed exhibits rapid response times, good stability, high repeatability, and biologically relevant sensitivity. We also developed and characterized a leak-free reference electrode that mitigates the potential cytotoxic effects of silver ions released from conventional reference electrodes. Using the resulting dual-purpose sensor, we performed hourly measurements of pH and phenylalanine concentrations in the medium superfusing cultured epithelial tumor cell lines (A549, MDA-MB-23) and a human fibroblast cell line (MRC-5) for periods of up to 72 h. Our scalable technology may be multiplexed for high-throughput monitoring of pH and multiple analytes in support of the broad metabolic qualification of microphysiological systems.
Authors
- J. ZIELINSKI (ORCID: https://orcid.org/0000-0002-6899-5564)
- Xumei Gao (ORCID: https://orcid.org/0000-0002-8799-3038)
- Ranjith Rajasekharan Unnithan (ORCID: https://orcid.org/0000-0002-1710-002X)
- Avanka Gunatilaka (ORCID: https://orcid.org/0000-0001-8181-7298)
- Bryce Widdicombe
- Kaylyn K. Leung (ORCID: https://orcid.org/0000-0002-8966-801X)
- Kevin W. Plaxco (ORCID: https://orcid.org/0000-0003-4772-8771)
- Alastair G. Stewart (ORCID: https://orcid.org/0000-0002-2271-5942)
- Tianhong Cheng (ORCID: https://orcid.org/0000-0002-9194-8678)
- Yiling Yang (ORCID: https://orcid.org/0009-0001-1947-2791)
- Xiaodan Zhang (ORCID: https://orcid.org/0000-0003-3827-1378)
Institutions
- University of California, Santa Barbara (US)
- The University of Melbourne (AU)
- Center for Personalized Cancer Treatment (NL)
- Personalis (United States) (US)
Publication Details
- Journal
- ACS Nano
- Published
- 2024-09-10
- DOI
- https://doi.org/10.1021/acsnano.4c06813
- Citations
- 11
- Primary Topic
- Analytical Chemistry and Sensors
- Type
- article
- Field-Weighted Citation Impact
- 3.18
Funders
- Australian National Fabrication Facility
- Medical Research Council
- Australian Research Council
- National Health and Medical Research Council