CPT and Lorentz symmetry tests with hydrogen using a novel in-beam hyperfine spectroscopy method applicable to antihydrogen experiments

We present a Rabi-type measurement of two ground-state hydrogen hyperfine transitions performed in two opposite external magnetic field directions. This puts first constraints at the level of Image 1 on a set of coefficients of the Standard Model Extension, which were not measured by previous experiments. Moreover, we introduce a novel method, applicable to antihydrogen hyperfine spectroscopy in a beam, that determines the zero-field hyperfine transition frequency from the two transitions measured at the same magnetic field. Our value, Image 2, is in agreement with literature at a relative precision of 0.44 ppb. This is the highest precision achieved on hydrogen in a beam, improving over previous results by a factor of 6.

Authors

Publication Details

Journal
Physics Letters B
Published
2024-09-10
DOI
https://doi.org/10.1016/j.physletb.2024.139012
Citations
6
Primary Topic
Atomic and Molecular Physics
Type
article
Field-Weighted Citation Impact
2.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CPT and Lorentz symmetry tests with hydrogen using a novel in-beam hyperfine spectroscopy method applicable to antihydrogen experiments

E. Widmann, M. Wiesinger, C. Malbrunot, M. C. Simon et al.
6 citations
Physics Letters B
Atomic and Molecular Physics
2.03
article

CPT and Lorentz symmetry tests with hydrogen using a novel in-beam hyperfine spectroscopy method applicable to antihydrogen experiments

E. Widmann, M. Wiesinger, C. Malbrunot, M. C. Simon, A. Nanda, T. Wolz, A. Lanz, L. Nowak, S. Arguedas Cuendis, C. Amsler, Sebastian Lahs
article en
6 citations

Abstract

We present a Rabi-type measurement of two ground-state hydrogen hyperfine transitions performed in two opposite external magnetic field directions. This puts first constraints at the level of Image 1 on a set of coefficients of the Standard Model Extension, which were not measured by previous experiments. Moreover, we introduce a novel method, applicable to antihydrogen hyperfine spectroscopy in a beam, that determines the zero-field hyperfine transition frequency from the two transitions measured at the same magnetic field. Our value, Image 2, is in agreement with literature at a relative precision of 0.44 ppb. This is the highest precision achieved on hydrogen in a beam, improving over previous results by a factor of 6.

Physics Letters BVol. 858
CERN, Austrian Science Fund
Affordable and clean energy
Openalex Percentile: Top 13%
Atomic and Molecular Physics
2.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.