A Multi-Functional Reactive Power Compensation Device with the Capability of Grounding Fault Regulation and Its Parameter Design Method

Aiming at the problems of low equipment utilization and the high-capacity requirements of existing arc-suppression devices, a multi-functional reactive power compensation device with the capability of grounding fault regulation (MF-RPCD) is proposed. Firstly, the topology and operation mechanism of MF-RPCD are introduced in this paper. MF-RPCD works in a reactive power compensation mode when a power grid is under normal operation to ensure the unit power factor operation of the power-grid side. When a single line-to-ground fault occurs in the power grid, MF-RPCD works in a fault-regulation mode to effectively suppress the ground-fault current. Secondly, the parameters of the active and passive parts of MF-RPCD are optimally designed to ensure the stable operation of MF-RPCD. Finally, the correctness, feasibility and effectiveness of the proposed topology and functions are verified using simulations and experiments.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-09-10
DOI
https://doi.org/10.3390/en17184531
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Multi-Functional Reactive Power Compensation Device with the Capability of Grounding Fault Regulation and Its Parameter Design Method

Qi Guo, Huaying Zhang, Zejun Huang, Yuchao Hou et al.
Energies
Power Systems Fault Detection
article

A Multi-Functional Reactive Power Compensation Device with the Capability of Grounding Fault Regulation and Its Parameter Design Method

Qi Guo, Huaying Zhang, Zejun Huang, Yuchao Hou, Huicong Liu, Xiaorui Liang
article en

Abstract

Aiming at the problems of low equipment utilization and the high-capacity requirements of existing arc-suppression devices, a multi-functional reactive power compensation device with the capability of grounding fault regulation (MF-RPCD) is proposed. Firstly, the topology and operation mechanism of MF-RPCD are introduced in this paper. MF-RPCD works in a reactive power compensation mode when a power grid is under normal operation to ensure the unit power factor operation of the power-grid side. When a single line-to-ground fault occurs in the power grid, MF-RPCD works in a fault-regulation mode to effectively suppress the ground-fault current. Secondly, the parameters of the active and passive parts of MF-RPCD are optimally designed to ensure the stable operation of MF-RPCD. Finally, the correctness, feasibility and effectiveness of the proposed topology and functions are verified using simulations and experiments.

EnergiesVol. 17(18)
Hunan University (CN), China Southern Power Grid (China) (CN)
China Southern Power Grid
Openalex Percentile: Top 84%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.