The Detailed Axial Compression Behavior of CFST Columns Infilled by Lightweight Concrete

The utilization of lightweight aggregate concrete (LWC) plays a major role in reducing the self-weight of CFST (concrete-filled steel tube) columns, which is reflected in the behavior of the structural system. This paper aims to investigate the characteristics of lightweight concrete-filled steel tubular (LWCFST) columns under an axial compressive load, using a total of (48) LWCFST column models. The simulated models were divided into four groups with different concrete compressive strength, length-to-diameter ratios (L/D), and diameter-to-thickness ratios (D/t). Four concrete compressive values were examined (30, 40, 50, and 60) MPa, three length-to-diameter ratios short (L/D = 3), medium (L/D = 6), and long (L/D = 9), and four diameter-to-thickness ratios (36, 31, 26, and 21). The method of nonlinear finite element analysis (NLFEA) was used to fulfill the objective of this study where results were presented as graphical plots between the compressive loading versus the axial and lateral strains along with the failure modes. In addition, the results were compared with the AISC360-16 and EC4 codes predictions to examine their applicability on the LWCFST columns where the AISC was overpredicted in most cases with higher percentages under lower (L/D) values, whereas the EC2 was underestimated in most cases with high percentages up to 28%, which become closer to the NLFEA predictions at higher (L/D) values. It has been revealed that the utilization of steel tubes significantly improves the LWCFST column’s mechanical performance, ductility, compressive strength, and toughness. Moreover, the structural behavior of the LWCFST columns and their associated failure modes was found to be highly affected by the geometrical properties of the CFST column (i.e., L/D ratio and D/t ratio) where specimens with small tube thickness show bad behavior. Finally, the utilization of high-strength concrete has a favorable performance compared to the utilization of thick steel tubes.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-09-10
DOI
https://doi.org/10.3390/buildings14092844
Citations
12
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
3.13
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Detailed Axial Compression Behavior of CFST Columns Infilled by Lightweight Concrete

Bara’a R. Alnemrawi, Rajai Z. Al‐Rousan
12 citations
Buildings
Structural Load-Bearing Analysis
3.13
article

The Detailed Axial Compression Behavior of CFST Columns Infilled by Lightweight Concrete

Bara’a R. Alnemrawi, Rajai Z. Al‐Rousan
article en
12 citations

Abstract

The utilization of lightweight aggregate concrete (LWC) plays a major role in reducing the self-weight of CFST (concrete-filled steel tube) columns, which is reflected in the behavior of the structural system. This paper aims to investigate the characteristics of lightweight concrete-filled steel tubular (LWCFST) columns under an axial compressive load, using a total of (48) LWCFST column models. The simulated models were divided into four groups with different concrete compressive strength, length-to-diameter ratios (L/D), and diameter-to-thickness ratios (D/t). Four concrete compressive values were examined (30, 40, 50, and 60) MPa, three length-to-diameter ratios short (L/D = 3), medium (L/D = 6), and long (L/D = 9), and four diameter-to-thickness ratios (36, 31, 26, and 21). The method of nonlinear finite element analysis (NLFEA) was used to fulfill the objective of this study where results were presented as graphical plots between the compressive loading versus the axial and lateral strains along with the failure modes. In addition, the results were compared with the AISC360-16 and EC4 codes predictions to examine their applicability on the LWCFST columns where the AISC was overpredicted in most cases with higher percentages under lower (L/D) values, whereas the EC2 was underestimated in most cases with high percentages up to 28%, which become closer to the NLFEA predictions at higher (L/D) values. It has been revealed that the utilization of steel tubes significantly improves the LWCFST column’s mechanical performance, ductility, compressive strength, and toughness. Moreover, the structural behavior of the LWCFST columns and their associated failure modes was found to be highly affected by the geometrical properties of the CFST column (i.e., L/D ratio and D/t ratio) where specimens with small tube thickness show bad behavior. Finally, the utilization of high-strength concrete has a favorable performance compared to the utilization of thick steel tubes.

BuildingsVol. 14(9)
Jordan University of Science and Technology (JO)
Openalex Percentile: Top 9%
Structural Load-Bearing Analysis
3.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Detailed Axial Compression Behavior of CFST Columns Infilled by Lightweight Concrete — Bara’a R. Alnemrawi, Rajai Z. Al‐Rousan · Buildings (2024) | TGRS Research Map | TGRS