Natural ventilation in large spaces: CFD simplified model validated with full-scale experimental data of Roman Baths

This study addresses the escalating need for energy-efficient and well-ventilated buildings by examining natural ventilation in large spaces. Validation of a CFD model was pursued through in-site experiments at the Roman Baths Museum in Chaves, Portugal. A sensitivity analysis aimed to determine the optimal number of monitoring points for model validation, crucial for establishing procedures in large-volume settings. Findings emphasized the feasibility of using a minimal number of monitored points, notably with a 3 × 3 test point arrangement, showcasing consistent temperature variations with low relative errors (0.50 %–1.75 %). Furthermore, the validated model assessed ventilation performance under diverse operational conditions, revealing slight enhancements in experimental settings, including an increase in air change rate (2.4 vs. 2.2 ACH) and a decrease in buoyancy dominance (Richardson number 197.3 vs. 241.3) compared to design conditions. Quantitative analysis highlighted similar temperature and velocity trends, with greater stratification in experimental conditions (temperature ratios 0.12 to 0.36 vs. 0.10 to 0.32). Qualitative assessments align with the quantitative analysis and enable the identification of stagnation zones and airflow distribution patterns. These findings affirm the methods' reliability in analysing ventilation in large spaces naturally ventilated, validating the model across diverse contexts, despite fewer data points. • Simplified model validated using is-situ data of large space. • Sensitivity analysis: monitoring with 26, 11, and 6 points. • Low relative errors: 0.5%–0.8 % (11 points), 1%–1.75 % (6 points). • Ventilation performance: ACH, Richardson numbers, temperature/velocity profiles. • Velocity maps reveal airflow patterns and recirculation zones.

Authors

Institutions

Publication Details

Journal
Building and Environment
Published
2024-09-10
DOI
https://doi.org/10.1016/j.buildenv.2024.112077
Citations
17
Primary Topic
Conservation Techniques and Studies
Type
article
Field-Weighted Citation Impact
33.24

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Natural ventilation in large spaces: CFD simplified model validated with full-scale experimental data of Roman Baths

J.M.C. Pereira, Rafaela Mateus, A. Pinto
17 citations
Building and Environment
Conservation Techniques and Studies
33.24
article

Natural ventilation in large spaces: CFD simplified model validated with full-scale experimental data of Roman Baths

J.M.C. Pereira, Rafaela Mateus, A. Pinto
article en
17 citations

Abstract

This study addresses the escalating need for energy-efficient and well-ventilated buildings by examining natural ventilation in large spaces. Validation of a CFD model was pursued through in-site experiments at the Roman Baths Museum in Chaves, Portugal. A sensitivity analysis aimed to determine the optimal number of monitoring points for model validation, crucial for establishing procedures in large-volume settings. Findings emphasized the feasibility of using a minimal number of monitored points, notably with a 3 × 3 test point arrangement, showcasing consistent temperature variations with low relative errors (0.50 %–1.75 %). Furthermore, the validated model assessed ventilation performance under diverse operational conditions, revealing slight enhancements in experimental settings, including an increase in air change rate (2.4 vs. 2.2 ACH) and a decrease in buoyancy dominance (Richardson number 197.3 vs. 241.3) compared to design conditions. Quantitative analysis highlighted similar temperature and velocity trends, with greater stratification in experimental conditions (temperature ratios 0.12 to 0.36 vs. 0.10 to 0.32). Qualitative assessments align with the quantitative analysis and enable the identification of stagnation zones and airflow distribution patterns. These findings affirm the methods' reliability in analysing ventilation in large spaces naturally ventilated, validating the model across diverse contexts, despite fewer data points. • Simplified model validated using is-situ data of large space. • Sensitivity analysis: monitoring with 26, 11, and 6 points. • Low relative errors: 0.5%–0.8 % (11 points), 1%–1.75 % (6 points). • Ventilation performance: ACH, Richardson numbers, temperature/velocity profiles. • Velocity maps reveal airflow patterns and recirculation zones.

Building and EnvironmentVol. 266
Instituto de Engenharia de Sistemas e Computadores Investigação e Desenvolvimento (PT), National Institute of Engineering, Technology and Innovation (PT), University of Lisbon (PT), National Laboratory for Civil Engineering (PT)
Fundação para a Ciência e a Tecnologia
Openalex Percentile: Top 0%
Conservation Techniques and Studies
33.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.