Getting the Best out of Capillary Electrophoresis and Capillary Electrophoresis–Mass Spectrometry by Quantifying Sources of Peak Broadening for Proteins Using Polyelectrolyte Multilayer Coated Fused Silica Capillaries

Capillary electrophoresis (CE) has emerged as a relevant technique for protein and biopharmaceutical analysis, as it combines high separation efficiency, sensitivity, and versatility. The use of capillary coatings, including successive multiple ionic-polymer layers (SMILs), reduces interactions between analytes and the capillary, further improving the CE performance. Nevertheless, separations done on SMIL coatings rarely surpass 500 × 10<sup>3</sup> plates/m. To obtain the best out of the CE, it is interesting to have a detailed look at the sources of peak dispersion. Separations of a mix of model proteins were performed on (poly(diallyldimethylammonium chloride)/poly(styrenesulfonate))<sub>2.5</sub>-coated capillaries at different electrical field strengths, leading to plate height <i>H</i> against migration velocity <i>u</i> plots that enabled a quantitative analysis of each contribution. Using this model, capillary lengths and injected volumes were systematically varied. For the first time, the contribution of sample electrophoretic heterogeneity to the total peak dispersion was deciphered for model proteins and a monoclonal antibody. Dispersion due to electromigration was seen to have an impact on plate heights in the case of triangular peaks of small molecules but not for proteins under the present conditions. UV and mass spectrometry detections were compared on the same capillary, providing valuable information on the impact of the detection type on separation efficiency. Close to 1 million plates/m were reached in the best conditions.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-09-10
DOI
https://doi.org/10.1021/acs.analchem.4c02276
Citations
5
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Getting the Best out of Capillary Electrophoresis and Capillary Electrophoresis–Mass Spectrometry by Quantifying Sources of Peak Broadening for Proteins Using Polyelectrolyte Multilayer Coated Fused Silica Capillaries

Michel Martin, Hervé Cottet, Alisa Höchsmann, Laurent Leclercq et al.
5 citations
Analytical Chemistry
Microfluidic and Capillary Electrophoresis Applications
0.92
article

Getting the Best out of Capillary Electrophoresis and Capillary Electrophoresis–Mass Spectrometry by Quantifying Sources of Peak Broadening for Proteins Using Polyelectrolyte Multilayer Coated Fused Silica Capillaries

Michel Martin, Hervé Cottet, Alisa Höchsmann, Laurent Leclercq, Laura Dhellemmes, Christian Neusüß
article en
5 citations

Abstract

Capillary electrophoresis (CE) has emerged as a relevant technique for protein and biopharmaceutical analysis, as it combines high separation efficiency, sensitivity, and versatility. The use of capillary coatings, including successive multiple ionic-polymer layers (SMILs), reduces interactions between analytes and the capillary, further improving the CE performance. Nevertheless, separations done on SMIL coatings rarely surpass 500 × 10<sup>3</sup> plates/m. To obtain the best out of the CE, it is interesting to have a detailed look at the sources of peak dispersion. Separations of a mix of model proteins were performed on (poly(diallyldimethylammonium chloride)/poly(styrenesulfonate))<sub>2.5</sub>-coated capillaries at different electrical field strengths, leading to plate height <i>H</i> against migration velocity <i>u</i> plots that enabled a quantitative analysis of each contribution. Using this model, capillary lengths and injected volumes were systematically varied. For the first time, the contribution of sample electrophoretic heterogeneity to the total peak dispersion was deciphered for model proteins and a monoclonal antibody. Dispersion due to electromigration was seen to have an impact on plate heights in the case of triangular peaks of small molecules but not for proteins under the present conditions. UV and mass spectrometry detections were compared on the same capillary, providing valuable information on the impact of the detection type on separation efficiency. Close to 1 million plates/m were reached in the best conditions.

Analytical Chemistry
École Nationale Supérieure de Chimie de Montpellier (FR), Centre National de la Recherche Scientifique (FR), Université de Montpellier (FR), Université Paris Cité (FR), Sorbonne Université (FR), Physique et Mécanique des Milieux Hétérogènes (FR), Hochschule Aalen (DE), Institut des Biomolécules Max Mousseron (FR), University of Tübingen (DE), ESPCI Paris (FR)
Deutsche Forschungsgemeinschaft, Agence Nationale de la Recherche
Openalex Percentile: Top 28%
Microfluidic and Capillary Electrophoresis Applications
0.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.