Stimulated Brillouin scattering flow cytometry

We present the use of stimulated Brillouin scattering spectroscopy to achieve rapid measurements of cell biomechanics in a flow cytometer setup. Specifically, our stimulated Brillouin scattering flow cytometry can acquire at a rate of 200 Hz, with a spectral acquisition time of 5 ms, which marks a 10x improvement compared to previous demonstrations of spontaneous Brillouin scattering flow cytometry. We experimentally validate our stimulated Brillouin scattering flow cytometer by measuring cell populations of normal breast epithelial cells and metastatic breast epithelial cancer cells.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2024-09-09
DOI
https://doi.org/10.1364/boe.537602
Citations
1
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stimulated Brillouin scattering flow cytometry

Giulia Zanini, Chenchen Handler, Michele Vítolo, Giuliano Scarcelli et al.
1 citations
Biomedical Optics Express
Microfluidic and Bio-sensing Technologies
0.18
article

Stimulated Brillouin scattering flow cytometry

Giulia Zanini, Chenchen Handler, Michele Vítolo, Giuliano Scarcelli, Stuart S. Martin, Jake R. Rosvold, Jiarui Li, Eric Frank
article en
1 citations

Abstract

We present the use of stimulated Brillouin scattering spectroscopy to achieve rapid measurements of cell biomechanics in a flow cytometer setup. Specifically, our stimulated Brillouin scattering flow cytometry can acquire at a rate of 200 Hz, with a spectral acquisition time of 5 ms, which marks a 10x improvement compared to previous demonstrations of spontaneous Brillouin scattering flow cytometry. We experimentally validate our stimulated Brillouin scattering flow cytometer by measuring cell populations of normal breast epithelial cells and metastatic breast epithelial cancer cells.

Biomedical Optics ExpressVol. 15(10)
University of Maryland, Baltimore (US), University of Maryland, College Park (US)
National Cancer Institute
Openalex Percentile: Top 53%
Microfluidic and Bio-sensing Technologies
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Stimulated Brillouin scattering flow cytometry — Giulia Zanini, Chenchen Handler, et al. · Biomedical Optics Express (2024) | TGRS Research Map | TGRS