Simple, cost-effective, highly stable solid-state photoluminescence standard for fluorometer calibration in low-resource settings

The proposed photoluminescence calibration standard comprises a solid-state phosphor film, neutral density gel filter(s), and a 3D-printed optomechanical cartridge. The proposed standard demonstrated exceptional photostability; photoluminescence did not deviate from the baseline more than 1.27% under 5 minutes of continuous illumination. Remarkably, there was no measurable degradation over a 3-year study. Precise photoluminescence intensity modulation was accomplished with neutral density gel filters (R<sup>2</sup> > 0.9982) and optical apertures (R<sup>2</sup> > 0.9970). A model for photoluminescence intensity as a function of neutral-density filter and optical aperture parameters yielded a mean percentage error (MPE) of 2.79%, indicating high precision. Inter-sample variability was low, with a mean coefficient of variation (CV) of 1.32%. Mean CV across 24 channels decreased from 11.88% to 1.51% following multi-point calibration of multichannel point-of-care (POC) fluorometers. Cost analysis revealed a per-unit cost between $0.49 to $1.80. This work suggests that the proposed calibration standards provide a cost-effective, highly stable solution for reliable fluorometer calibration in low-resource settings.

Authors

Institutions

Publication Details

Journal
Optics Continuum
Published
2024-09-09
DOI
https://doi.org/10.1364/optcon.534029
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simple, cost-effective, highly stable solid-state photoluminescence standard for fluorometer calibration in low-resource settings

Jennifer Blain Christen, Joshua Eger, Mark Bailly
Optics Continuum
Analytical Chemistry and Sensors
article

Simple, cost-effective, highly stable solid-state photoluminescence standard for fluorometer calibration in low-resource settings

Jennifer Blain Christen, Joshua Eger, Mark Bailly
article en

Abstract

The proposed photoluminescence calibration standard comprises a solid-state phosphor film, neutral density gel filter(s), and a 3D-printed optomechanical cartridge. The proposed standard demonstrated exceptional photostability; photoluminescence did not deviate from the baseline more than 1.27% under 5 minutes of continuous illumination. Remarkably, there was no measurable degradation over a 3-year study. Precise photoluminescence intensity modulation was accomplished with neutral density gel filters (R<sup>2</sup> > 0.9982) and optical apertures (R<sup>2</sup> > 0.9970). A model for photoluminescence intensity as a function of neutral-density filter and optical aperture parameters yielded a mean percentage error (MPE) of 2.79%, indicating high precision. Inter-sample variability was low, with a mean coefficient of variation (CV) of 1.32%. Mean CV across 24 channels decreased from 11.88% to 1.51% following multi-point calibration of multichannel point-of-care (POC) fluorometers. Cost analysis revealed a per-unit cost between $0.49 to $1.80. This work suggests that the proposed calibration standards provide a cost-effective, highly stable solution for reliable fluorometer calibration in low-resource settings.

Optics ContinuumVol. 3(11)
BioElectronics (United States) (US), Arizona State University (US)
National Cancer Institute
Openalex Percentile: Top 86%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simple, cost-effective, highly stable solid-state photoluminescence standard for fluorometer calibration in low-resource settings — Jennifer Blain Christen, Joshua Eger, et al. · Optics Continuum (2024) | TGRS Research Map | TGRS