Assessment of fluid responsiveness after tidal volume challenge in renal transplant recipients: a nonrandomized prospective interventional study

BACKGROUND: When applying lung-protective ventilation, fluid responsiveness cannot be predicted by pulse pressure variation (PPV) or stroke volume variation (SVV). Functional hemodynamic testing may help address this limitation. This study examined whether changes in dynamic indices such as PPV and SVV, induced by tidal volume challenge (TVC), can reliably predict fluid responsiveness in patients undergoing renal transplantation who receive lung-protective ventilation. METHODS: This nonrandomized interventional study included renal transplant recipients with end-stage renal disease. Patients received ventilation with a 6 mL/kg tidal volume (TV), and the FloTrac system was attached for continuous hemodynamic monitoring. Participants were classified as responders or nonresponders based on whether fluid challenge increased the stroke volume index by more than 10%. RESULTS: The analysis included 36 patients, of whom 19 (52.8%) were responders and 17 (47.2%) were nonresponders. Among responders, the mean ΔPPV(6-8) (calculated as PPV at a TV of 8 mL/kg predicted body weight [PBW] minus that at 6 mL/kg PBW) was 3.32±0.75 and ΔSVV(6-8) was 2.58±0.77, compared to 0.82±0.53 and 0.70±0.92 for nonresponders, respectively. ΔPPV(6-8) exhibited an area under the curve (AUC) of 0.97 (95% confidence interval [CI], 0.93–1.00; P≤0.001), with an optimal cutoff value of 1.5, sensitivity of 94.7%, and specificity of 94.1%. ΔSVV(6-8) displayed an AUC of 0.93 (95% CI, 0.84–1.00; P≤0.001) at the same cutoff value of 1.5, with a sensitivity of 94.7% and a specificity of 76.5%. CONCLUSIONS: TVC-induced changes in PPV and SVV are predictive of fluid responsiveness in renal transplant recipients who receive intraoperative lung-protective ventilation.

Authors

Institutions

Publication Details

Journal
Clinical Transplantation and Research
Published
2024-09-09
DOI
https://doi.org/10.4285/ctr.24.0025
Citations
4
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
2.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of fluid responsiveness after tidal volume challenge in renal transplant recipients: a nonrandomized prospective interventional study

Praveenkumar Shekhrajka, Saurabh Mittal, Akash Mishra, Ganesh Ramaji Nimje et al.
4 citations
Clinical Transplantation and Research
Hemodynamic Monitoring and Therapy
2.29
article

Assessment of fluid responsiveness after tidal volume challenge in renal transplant recipients: a nonrandomized prospective interventional study

Praveenkumar Shekhrajka, Saurabh Mittal, Akash Mishra, Ganesh Ramaji Nimje, Pankaj Singh, Vipin Kumar Goyal
article en
4 citations

Abstract

BACKGROUND: When applying lung-protective ventilation, fluid responsiveness cannot be predicted by pulse pressure variation (PPV) or stroke volume variation (SVV). Functional hemodynamic testing may help address this limitation. This study examined whether changes in dynamic indices such as PPV and SVV, induced by tidal volume challenge (TVC), can reliably predict fluid responsiveness in patients undergoing renal transplantation who receive lung-protective ventilation. METHODS: This nonrandomized interventional study included renal transplant recipients with end-stage renal disease. Patients received ventilation with a 6 mL/kg tidal volume (TV), and the FloTrac system was attached for continuous hemodynamic monitoring. Participants were classified as responders or nonresponders based on whether fluid challenge increased the stroke volume index by more than 10%. RESULTS: The analysis included 36 patients, of whom 19 (52.8%) were responders and 17 (47.2%) were nonresponders. Among responders, the mean ΔPPV(6-8) (calculated as PPV at a TV of 8 mL/kg predicted body weight [PBW] minus that at 6 mL/kg PBW) was 3.32±0.75 and ΔSVV(6-8) was 2.58±0.77, compared to 0.82±0.53 and 0.70±0.92 for nonresponders, respectively. ΔPPV(6-8) exhibited an area under the curve (AUC) of 0.97 (95% confidence interval [CI], 0.93–1.00; P≤0.001), with an optimal cutoff value of 1.5, sensitivity of 94.7%, and specificity of 94.1%. ΔSVV(6-8) displayed an AUC of 0.93 (95% CI, 0.84–1.00; P≤0.001) at the same cutoff value of 1.5, with a sensitivity of 94.7% and a specificity of 76.5%. CONCLUSIONS: TVC-induced changes in PPV and SVV are predictive of fluid responsiveness in renal transplant recipients who receive intraoperative lung-protective ventilation.

Clinical Transplantation and ResearchVol. 38(3)
Gandhi Medical College & Hospital (IN)
Openalex Percentile: Top 12%
Hemodynamic Monitoring and Therapy
2.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.