This study aims to investigate, using patient studies, the impact of Injected Dose (ID), Body Mass Index (BMI), and image noise assessments in PET imaging. This study included 59 liver cancer patients weighing between 45 and 107 kg. After intravenously injecting 0.1 millicurie (mCi) of 18F-FDG per kilogram of body weight, PET scans were obtained for 1, 1.5, and 3 min/bed position based on the patient's weight. Weight, height, and body mass index were calculated using a spreadsheet. Five regions of interest (ROIs) were placed at the same site in the liver, which was considered to have a homogeneous metabolism, in five successive slices of PET/CT scans to determine the mean uptake (signal) values and their standard deviation (noise). The ratio of both gives the liver's Signal-to-Noise Ratio (SNR). Graphs were created to determine the relationship between these characteristics. The plots demonstrated that the dose injected increased when body weight and/or BMI increased, and that the SNR fell even as the dose administered increased. This is owing to the fact that heavier patients having a higher administered dose and, have a lower SNR even when greater 18F-FDG doses are delivered. These data indicate that the image quality, as measured by the SNR, is inferior in heavier persons compared to those who are thinner.

Authors

Publication Details

Journal
Iraqi Journal of Science
Published
2024-09-09
DOI
https://doi.org/10.24996/ijs.2024.65.8(si).2
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Effect of the Injected Dose and Body Mass Index on the Signal-to-Noise Ratio (SNR) Detected using a PET/CT Scan.

Samar I. Essa, Aya B. Hade
Iraqi Journal of Science
Digital Radiography and Breast Imaging
article

Evaluation of the Effect of the Injected Dose and Body Mass Index on the Signal-to-Noise Ratio (SNR) Detected using a PET/CT Scan.

Samar I. Essa, Aya B. Hade
article en

Abstract

This study aims to investigate, using patient studies, the impact of Injected Dose (ID), Body Mass Index (BMI), and image noise assessments in PET imaging. This study included 59 liver cancer patients weighing between 45 and 107 kg. After intravenously injecting 0.1 millicurie (mCi) of 18F-FDG per kilogram of body weight, PET scans were obtained for 1, 1.5, and 3 min/bed position based on the patient's weight. Weight, height, and body mass index were calculated using a spreadsheet. Five regions of interest (ROIs) were placed at the same site in the liver, which was considered to have a homogeneous metabolism, in five successive slices of PET/CT scans to determine the mean uptake (signal) values and their standard deviation (noise). The ratio of both gives the liver's Signal-to-Noise Ratio (SNR). Graphs were created to determine the relationship between these characteristics. The plots demonstrated that the dose injected increased when body weight and/or BMI increased, and that the SNR fell even as the dose administered increased. This is owing to the fact that heavier patients having a higher administered dose and, have a lower SNR even when greater 18F-FDG doses are delivered. These data indicate that the image quality, as measured by the SNR, is inferior in heavier persons compared to those who are thinner.

Iraqi Journal of Science
Good health and well-being
Openalex Percentile: Top 73%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of the Effect of the Injected Dose and Body Mass Index on the Signal-to-Noise Ratio (SNR) Detected using a PET/CT Scan. — Samar I. Essa, Aya B. Hade · Iraqi Journal of Science (2024) | TGRS Research Map | TGRS