Benefits of front coating crystalline scintillator screens for phase-contrast synchrotron micro-tomography

Transparent crystalline scintillators such as cerium-doped YAG or LuAG are widely used in X-ray imaging for the indirect detection of X-rays. The application of reflective coatings on the front side to improve the optical gain is common practice for flat panel detectors with CsI or Gd<sub>2</sub>O<sub>2</sub>S powder scintillators but still largely unknown for crystalline scintillators such as LuAG. This work shows experimentally and quantitatively how a black and reflective coating on the X-ray side of a 2 mm LuAG:Ce scintillator improves the image quality compared to a 2 mm LuAG:Ce scintillator without a coating. The measurements have been done for two different distances, with 2 m and 29.7 m on the BM18 beamline of the European Synchrotron. The Modulation Transfer Function (MTF) and the Signal-to-Noise-Ratio (SNR<sup>2</sup>) power spectrum as well as contrast-to-noise ratio are used for comparing image quality. Propagation-based phase contrast strongly enhances the SNR<sup>2</sup> amplitudes (gain ≈10 from 2 m to 29.7 m object-detector distance) of the raw images' spectrum independent of the scintillator coating. For both detector positions, the reflective coating is able to raise SNR<sup>2</sup> by up to 80% through the improved optical gain, while black coating does the opposite (decrease SNR<sup>2</sup> by 20%) with respect to no coating. With the tested optical setups, changes in MTF /sharpness between the coatings are minor. Comparing CNR<sup>2</sup> in CT scans of a multi-material sample, in this case an electric motor, we observe the reflective coating yielding better material contrast for plastic and air. Application and effect of Wiener-deconvolution, along with Paganin-type phase retrieval, are also discussed in the context of CT image quality.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2024-09-09
DOI
https://doi.org/10.1364/oe.534383
Citations
2
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
1.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Benefits of front coating crystalline scintillator screens for phase-contrast synchrotron micro-tomography

Matthias Diez, Paul Tafforeau, Simon Zabler, Nasila Saeidnezhad
2 citations
Optics Express
Advanced X-ray Imaging Techniques
1.22
article

Benefits of front coating crystalline scintillator screens for phase-contrast synchrotron micro-tomography

Matthias Diez, Paul Tafforeau, Simon Zabler, Nasila Saeidnezhad
article en
2 citations

Abstract

Transparent crystalline scintillators such as cerium-doped YAG or LuAG are widely used in X-ray imaging for the indirect detection of X-rays. The application of reflective coatings on the front side to improve the optical gain is common practice for flat panel detectors with CsI or Gd<sub>2</sub>O<sub>2</sub>S powder scintillators but still largely unknown for crystalline scintillators such as LuAG. This work shows experimentally and quantitatively how a black and reflective coating on the X-ray side of a 2 mm LuAG:Ce scintillator improves the image quality compared to a 2 mm LuAG:Ce scintillator without a coating. The measurements have been done for two different distances, with 2 m and 29.7 m on the BM18 beamline of the European Synchrotron. The Modulation Transfer Function (MTF) and the Signal-to-Noise-Ratio (SNR<sup>2</sup>) power spectrum as well as contrast-to-noise ratio are used for comparing image quality. Propagation-based phase contrast strongly enhances the SNR<sup>2</sup> amplitudes (gain ≈10 from 2 m to 29.7 m object-detector distance) of the raw images' spectrum independent of the scintillator coating. For both detector positions, the reflective coating is able to raise SNR<sup>2</sup> by up to 80% through the improved optical gain, while black coating does the opposite (decrease SNR<sup>2</sup> by 20%) with respect to no coating. With the tested optical setups, changes in MTF /sharpness between the coatings are minor. Comparing CNR<sup>2</sup> in CT scans of a multi-material sample, in this case an electric motor, we observe the reflective coating yielding better material contrast for plastic and air. Application and effect of Wiener-deconvolution, along with Paganin-type phase retrieval, are also discussed in the context of CT image quality.

Optics ExpressVol. 32(23)
European Synchrotron Radiation Facility (FR), Deggendorf Institute of Technology (DE)
Openalex Percentile: Top 21%
Advanced X-ray Imaging Techniques
1.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.