Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2024-09-09
DOI
https://doi.org/10.1364/oe.535325
Citations
8
Primary Topic
Random lasers and scattering media
Type
article
Field-Weighted Citation Impact
2.22

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantum ghost imaging microscopy depth-of-field study

Dominique Davenport, Edoardo Charbon, Mike Rushford, Ashleigh K. Wilson et al.
8 citations
Optics Express
Random lasers and scattering media
2.22
article

Quantum ghost imaging microscopy depth-of-field study

Dominique Davenport, Edoardo Charbon, Mike Rushford, Ashleigh K. Wilson, Brandon Demory, Audrey Eshun, Claudio Bruschini, Sam Jeppson, Ted A. Laurence, Paul Moş, Lin Yang, Shervin Kiannejad, Tiziana Bond, Michael Wayne, Charles D. Boley
article en
8 citations

Abstract

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

Optics ExpressVol. 32(20)
École Polytechnique Fédérale de Lausanne (CH)
U.S. Department of Energy, Biological and Environmental Research
Openalex Percentile: Top 11%
Random lasers and scattering media
2.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.