Enhancing Cone-Beam CT Image Quality in TIPSS Procedures Using AI Denoising

<i>Purpose:</i> This study evaluates a deep learning-based denoising algorithm to improve the trade-off between radiation dose, image noise, and motion artifacts in TIPSS procedures, aiming for shorter acquisition times and reduced radiation with maintained diagnostic quality. <i>Methods:</i> In this retrospective study, TIPSS patients were divided based on CBCT acquisition times of 6 s and 3 s. Traditional weighted filtered back projection (Original) and an AI denoising algorithm (AID) were used for image reconstructions. Objective assessments of image quality included contrast, noise levels, and contrast-to-noise ratios (CNRs) through place-consistent region-of-interest (ROI) measurements across various critical areas pertinent to the TIPSS procedure. Subjective assessments were conducted by two blinded radiologists who evaluated the overall image quality, sharpness, contrast, and motion artifacts for each dataset combination. Statistical significance was determined using a mixed-effects model (<i>p</i> ≤ 0.05). <i>Results:</i> From an initial cohort of 60 TIPSS patients, 44 were selected and paired. The mean dose-area product (DAP) for the 6 s acquisitions was 5138.50 ± 1325.57 µGy·m<sup>2</sup>, significantly higher than the 2514.06 ± 691.59 µGym<sup>2</sup> obtained for the 3 s series. CNR was highest in the 6 s-AID series (<i>p</i> < 0.05). Both denoised and original series showed consistent contrast for 6 s and 3 s acquisitions, with no significant noise differences between the 6 s Original and 3 s AID images (<i>p</i> > 0.9). Subjective assessments indicated superior quality in 6 s-AID images, with no significant overall quality difference between the 6 s-Original and 3 s-AID series (<i>p</i> > 0.9). <i>Conclusions:</i> The AI denoising algorithm enhances CBCT image quality in TIPSS procedures, allowing for shorter scans that reduce radiation exposure and minimize motion artifacts.

Authors

Publication Details

Journal
Diagnostics
Published
2024-09-09
DOI
https://doi.org/10.3390/diagnostics14171989
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Cone-Beam CT Image Quality in TIPSS Procedures Using AI Denoising

Patrick Ghibes, Andreas Brendlin, Konstantin Nikolaou, Sebastian Gassenmaier et al.
2 citations
Diagnostics
Medical Imaging Techniques and Applications
0.81
article

Enhancing Cone-Beam CT Image Quality in TIPSS Procedures Using AI Denoising

Patrick Ghibes, Andreas Brendlin, Konstantin Nikolaou, Sebastian Gassenmaier, Reza Dehdab, Haidara Almansour, Saif Afat, Jan M. Brendel, Gerd Grözinger, Sebastian Werner
article en
2 citations

Abstract

<i>Purpose:</i> This study evaluates a deep learning-based denoising algorithm to improve the trade-off between radiation dose, image noise, and motion artifacts in TIPSS procedures, aiming for shorter acquisition times and reduced radiation with maintained diagnostic quality. <i>Methods:</i> In this retrospective study, TIPSS patients were divided based on CBCT acquisition times of 6 s and 3 s. Traditional weighted filtered back projection (Original) and an AI denoising algorithm (AID) were used for image reconstructions. Objective assessments of image quality included contrast, noise levels, and contrast-to-noise ratios (CNRs) through place-consistent region-of-interest (ROI) measurements across various critical areas pertinent to the TIPSS procedure. Subjective assessments were conducted by two blinded radiologists who evaluated the overall image quality, sharpness, contrast, and motion artifacts for each dataset combination. Statistical significance was determined using a mixed-effects model (<i>p</i> ≤ 0.05). <i>Results:</i> From an initial cohort of 60 TIPSS patients, 44 were selected and paired. The mean dose-area product (DAP) for the 6 s acquisitions was 5138.50 ± 1325.57 µGy·m<sup>2</sup>, significantly higher than the 2514.06 ± 691.59 µGym<sup>2</sup> obtained for the 3 s series. CNR was highest in the 6 s-AID series (<i>p</i> < 0.05). Both denoised and original series showed consistent contrast for 6 s and 3 s acquisitions, with no significant noise differences between the 6 s Original and 3 s AID images (<i>p</i> > 0.9). Subjective assessments indicated superior quality in 6 s-AID images, with no significant overall quality difference between the 6 s-Original and 3 s-AID series (<i>p</i> > 0.9). <i>Conclusions:</i> The AI denoising algorithm enhances CBCT image quality in TIPSS procedures, allowing for shorter scans that reduce radiation exposure and minimize motion artifacts.

DiagnosticsVol. 14(17)
Eberhard Karls Universität Tübingen
Partnerships for the goals
Openalex Percentile: Top 26%
Medical Imaging Techniques and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.