ThP5.2 - Comparison of perioperative outcomes of open (CUSA) versus laparoscopic (LOTUS) major hepatectomy – revisited. First evaluation of efficacy and safety of AEON stapler

Abstract Introduction In 2019, preliminary data matching 40 cases demonstrated improved outcomes of laparoscopic major liver resections using the BOWA-LOTUS liver blade (Devon, UK). An updated and expanded comparison between open and laparoscopic major hepatectomies is presented as well as evaluating of an endovascular stapler AEON™ (Lexington Medical, Massachusetts, USA). Methods January 2020 to June 2023 patients were identified from a prospectively maintained database. Propensity score matching analysis used R statistical tool in SPSS (IBM, New York, USA) to isolate matched open and laparoscopic cases. LOTUS ultrasonic energy device was used for parenchymal transection in laparoscopic cases and CUSA (Valleylab, Colorado, USA) in open procedures. AEON endovascular stapler was used from early 2021. Results 86 patients constitute the study population after applying propensity score matching analysis in a 1:1 ratio. The median (range) age in the matched sample was 63 (27-83) yrs. Hospital stay (mean 7.8 v 14.7 days; p=0.025) and blood transfusion requirement (0 v 4 units; p=0.035) were all significantly improved when comparing laparoscopic to open. Comparison of the AEON stapler with Endo-GIA (Medtronic, MN, USA) showed no significant difference in any outcome measure, although AEON demonstrated (non-significantly) a reduced trend in operating time comparing all cases (56 v 69 mins; p=0.300) and laparoscopic (56 v 71 min; p=0.295). Conclusion The LOTUS liver blade continues to be associated with acceptable outcomes in laparoscopic liver resections. The AEON endovascular stapler was equivalent to other staplers with a trend towards a shorter operating time in liver transectional surgery.

Authors

Institutions

Publication Details

Journal
British journal of surgery
Published
2024-09-01
DOI
https://doi.org/10.1093/bjs/znae197.276
Primary Topic
Hepatocellular Carcinoma Treatment and Prognosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ThP5.2 - Comparison of perioperative outcomes of open (CUSA) versus laparoscopic (LOTUS) major hepatectomy – revisited. First evaluation of efficacy and safety of AEON stapler

Ajith K. Siriwardena, Affan Iqbal, Minas Baltatzis, Saurabh Jamdar et al.
British journal of surgery
Hepatocellular Carcinoma Treatment and Prognosis
article

ThP5.2 - Comparison of perioperative outcomes of open (CUSA) versus laparoscopic (LOTUS) major hepatectomy – revisited. First evaluation of efficacy and safety of AEON stapler

Ajith K. Siriwardena, Affan Iqbal, Minas Baltatzis, Saurabh Jamdar, Aali J. Sheen, P. Stathakis
article en

Abstract

Abstract Introduction In 2019, preliminary data matching 40 cases demonstrated improved outcomes of laparoscopic major liver resections using the BOWA-LOTUS liver blade (Devon, UK). An updated and expanded comparison between open and laparoscopic major hepatectomies is presented as well as evaluating of an endovascular stapler AEON™ (Lexington Medical, Massachusetts, USA). Methods January 2020 to June 2023 patients were identified from a prospectively maintained database. Propensity score matching analysis used R statistical tool in SPSS (IBM, New York, USA) to isolate matched open and laparoscopic cases. LOTUS ultrasonic energy device was used for parenchymal transection in laparoscopic cases and CUSA (Valleylab, Colorado, USA) in open procedures. AEON endovascular stapler was used from early 2021. Results 86 patients constitute the study population after applying propensity score matching analysis in a 1:1 ratio. The median (range) age in the matched sample was 63 (27-83) yrs. Hospital stay (mean 7.8 v 14.7 days; p=0.025) and blood transfusion requirement (0 v 4 units; p=0.035) were all significantly improved when comparing laparoscopic to open. Comparison of the AEON stapler with Endo-GIA (Medtronic, MN, USA) showed no significant difference in any outcome measure, although AEON demonstrated (non-significantly) a reduced trend in operating time comparing all cases (56 v 69 mins; p=0.300) and laparoscopic (56 v 71 min; p=0.295). Conclusion The LOTUS liver blade continues to be associated with acceptable outcomes in laparoscopic liver resections. The AEON endovascular stapler was equivalent to other staplers with a trend towards a shorter operating time in liver transectional surgery.

British journal of surgeryVol. 111(Supplement_8)
Manchester Royal Infirmary (GB), University of Manchester (GB)
Openalex Percentile: Top 75%
Hepatocellular Carcinoma Treatment and Prognosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.