SP6.3 - Comparison of three new wireless non-radiation techniques for localization of non-palpable breast cancer - an updated systematic review and pooled meta-analysis

Abstract The method for finding non-palpable breast cancers has evolved due to technological advancements. New wire-free techniques have made implantation and retrieval easier with improved oncological outcomes. Although some evidences are available as to reduced requirement for re-operation with wireless techniques when compared to wire, in current clinical practice, the choice of selection amongst wireless technique depends on clinician preference and there is a lack of consensus. The objective of current systematic review and meta-analysis is to assess the clinical effectiveness between three new wireless non radiation localisation techniques, such as Magseed (Magnetic seed), Radiofrequency identification tag (RFID) and Savi-scout reflector localization from published literature over the last 3 years. Literature search as per PRISMA guidelines revealed twenty-six studies from 2020 to 2022 involving 6275 innovative agents analysing the 3 groups were identified. Statistical analysis using Medcalc software showed a pooled positive margin rate of 12.28% (95% CI, 10 -15%) and a re-excision rate of 11.29% (95%CI, 9 -14%) for all 3 innovative technique combined whereas studies that compare innovative techniques with wire, showed higher positive margin rate of 14.87% (95% CI, 12-18%) and re-excision rate of 16.23% (95% CI, 14-18%) for wire localization, along with considerable heterogeneity. In sub group analysis with Kruskal-Wallis test, there were no statistical significance for margin (p 0.797) and re-operation (p 0.464) rates between each group. Consolidated insertion and retrieval success for innovative group were 98.13% and 99.13% respectively. To establish the best localization approach, future RCT's will be required to assess quantitative cost-effective analyses.

Authors

Institutions

Publication Details

Journal
British journal of surgery
Published
2024-09-01
DOI
https://doi.org/10.1093/bjs/znae197.068
Primary Topic
Breast Lesions and Carcinomas
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SP6.3 - Comparison of three new wireless non-radiation techniques for localization of non-palpable breast cancer - an updated systematic review and pooled meta-analysis

Vijay Kurup, Abdolazeem Elnour, Kumaresh Timma Subramanian
British journal of surgery
Breast Lesions and Carcinomas
article

SP6.3 - Comparison of three new wireless non-radiation techniques for localization of non-palpable breast cancer - an updated systematic review and pooled meta-analysis

Vijay Kurup, Abdolazeem Elnour, Kumaresh Timma Subramanian
article en

Abstract

Abstract The method for finding non-palpable breast cancers has evolved due to technological advancements. New wire-free techniques have made implantation and retrieval easier with improved oncological outcomes. Although some evidences are available as to reduced requirement for re-operation with wireless techniques when compared to wire, in current clinical practice, the choice of selection amongst wireless technique depends on clinician preference and there is a lack of consensus. The objective of current systematic review and meta-analysis is to assess the clinical effectiveness between three new wireless non radiation localisation techniques, such as Magseed (Magnetic seed), Radiofrequency identification tag (RFID) and Savi-scout reflector localization from published literature over the last 3 years. Literature search as per PRISMA guidelines revealed twenty-six studies from 2020 to 2022 involving 6275 innovative agents analysing the 3 groups were identified. Statistical analysis using Medcalc software showed a pooled positive margin rate of 12.28% (95% CI, 10 -15%) and a re-excision rate of 11.29% (95%CI, 9 -14%) for all 3 innovative technique combined whereas studies that compare innovative techniques with wire, showed higher positive margin rate of 14.87% (95% CI, 12-18%) and re-excision rate of 16.23% (95% CI, 14-18%) for wire localization, along with considerable heterogeneity. In sub group analysis with Kruskal-Wallis test, there were no statistical significance for margin (p 0.797) and re-operation (p 0.464) rates between each group. Consolidated insertion and retrieval success for innovative group were 98.13% and 99.13% respectively. To establish the best localization approach, future RCT's will be required to assess quantitative cost-effective analyses.

British journal of surgeryVol. 111(Supplement_8)
North Tees and Hartlepool NHS Foundation Trust (GB), Hywel Dda University Health Board (GB), Manchester University (US)
Openalex Percentile: Top 76%
Breast Lesions and Carcinomas
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.