Sensor Placement for Rupture Detection Using a Continuous Monitoring Strategy
This work proposes an analysis of the active monitoring method for rupture detection. The analysis regards the effect of sensor sensibility on the effectiveness of the localization method. This paper approaches the problem in two steps: the first step regards the detection of ruptures according to a method based on a sensitivity matrix and correlation analysis. The second step regards the selection of an effective sensor placement strategy. The aim is to determine the most effective position in terms of rupture localization ability of a predetermined number of sensors using sensor sensibility within the input variables.
Authors
- Giacomo Ferrarese (ORCID: https://orcid.org/0000-0001-8310-8241)
- Stefano Malavasi (ORCID: https://orcid.org/0000-0003-3881-1055)
- Elena Batzella
Institutions
- Politecnico di Milano (IT)
Publication Details
- Published
- 2024-09-09
- DOI
- https://doi.org/10.3390/engproc2024069091
- Primary Topic
- Geophysical Methods and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00