ThP2.5 - Number of lymph nodes removed in SLNB: comparison between standard technique versus Magtrace from a single-centre study

Abstract Introduction Sentinel lymph node biopsy (SLNB) is a precise method for axillary staging in early breast cancer. Historically, the standard approach used radioisotope, often combined with blue dye, for localising the sentinel lymph node (SLN). Recently, the introduction of the superparamagnetic iron oxide mapping agent, Magtrace, offers an alternative. Following the adoption of Magtrace, there was a perception that more nodes were being removed during SLNB. This study aims to compare the number of lymph nodes removed, during SLNB, between both techniques. Methods A retrospective single-centre study (2022-2023) included 316 patients undergoing SLNB at Royal Lancaster Infirmary. Before the late 2022 adoption of Magtrace, the standard technique involved radioisotope+/-blue dye. Subsequently, based on consultant preference, patients received Magtrace alone or with blue dye. The comparison focused on the number of identified SLN between the magnetic and standard techniques. Results Data from 316 patients was analysed across two periods: March to October 2022 (standard technique n=160), and March to October 2023 (Magtrace n=120; Magtrace+blue dye n=30; blue dye only n=5). Comparative analysis of the number of nodes removed produced the following results: standard technique 2.425, magnetic technique alone 2.403, magnetic technique with blue dye 2.133, and blue dye only 1.6. Conclusion Despite initial concerns regarding the perceived increase in the number of nodes removed during SLNB with the implementation of the Magtrace technique, our study reveals that the use of this technique results in a reduction in the number SLNs removed in comparison to the standard dual technique.

Authors

Institutions

Publication Details

Journal
British journal of surgery
Published
2024-09-01
DOI
https://doi.org/10.1093/bjs/znae197.240
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ThP2.5 - Number of lymph nodes removed in SLNB: comparison between standard technique versus Magtrace from a single-centre study

Rute Castelhano, Penelope McManus, Chandana Gavisiddappa
British journal of surgery
Lung Cancer Diagnosis and Treatment
article

ThP2.5 - Number of lymph nodes removed in SLNB: comparison between standard technique versus Magtrace from a single-centre study

Rute Castelhano, Penelope McManus, Chandana Gavisiddappa
article en

Abstract

Abstract Introduction Sentinel lymph node biopsy (SLNB) is a precise method for axillary staging in early breast cancer. Historically, the standard approach used radioisotope, often combined with blue dye, for localising the sentinel lymph node (SLN). Recently, the introduction of the superparamagnetic iron oxide mapping agent, Magtrace, offers an alternative. Following the adoption of Magtrace, there was a perception that more nodes were being removed during SLNB. This study aims to compare the number of lymph nodes removed, during SLNB, between both techniques. Methods A retrospective single-centre study (2022-2023) included 316 patients undergoing SLNB at Royal Lancaster Infirmary. Before the late 2022 adoption of Magtrace, the standard technique involved radioisotope+/-blue dye. Subsequently, based on consultant preference, patients received Magtrace alone or with blue dye. The comparison focused on the number of identified SLN between the magnetic and standard techniques. Results Data from 316 patients was analysed across two periods: March to October 2022 (standard technique n=160), and March to October 2023 (Magtrace n=120; Magtrace+blue dye n=30; blue dye only n=5). Comparative analysis of the number of nodes removed produced the following results: standard technique 2.425, magnetic technique alone 2.403, magnetic technique with blue dye 2.133, and blue dye only 1.6. Conclusion Despite initial concerns regarding the perceived increase in the number of nodes removed during SLNB with the implementation of the Magtrace technique, our study reveals that the use of this technique results in a reduction in the number SLNs removed in comparison to the standard dual technique.

British journal of surgeryVol. 111(Supplement_8)
Royal Lancaster Infirmary (GB)
Openalex Percentile: Top 73%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ThP2.5 - Number of lymph nodes removed in SLNB: comparison between standard technique versus Magtrace from a single-centre study — Rute Castelhano, Penelope McManus, et al. · British journal of surgery (2024) | TGRS Research Map | TGRS