Calibration of a gamma ray Compton camera for radioactivity measurements

Abstract A dual-plane Compton imaging detector previously developed for prompt gamma imaging has been further tested and calibrated for quantitative radioactivity determination, specifically to assess radioactive debris from a reactor fuel element. The debris piece contains uranium isotopes and several long-lived fission products, including cesium-137 (Cs-137). The detector consists of two pixelated planes of cadmium-zinc-telluride (CZT) crystals which record gamma ray events interacting within these volumes. In addition to the energy spectrum obtained by pulse height analysis, the time-stamped events from each detector pixel are sorted by location into 3 categories for post-processing: intra-plane, inter-plane, and coincidence. An image reconstruction software enables spatial localization of the select gamma ray peak(s) from the spectrum, thereby separating the gamma ray by specific isotopes. We used the camera to image a small piece of debris for demonstration purposes. A measurement was performed alongside a high purity germanium (HPGe) detector, which could determine the isotopes' absolute activities and be used as a reference for the camera. In addition, a known isotopic point source was used to calibrate the camera’s energy detection efficiency in the same measurement geometry, correlating the image pixel intensity to the isotopic activity.

Authors

Institutions

Publication Details

Journal
Journal of Radioanalytical and Nuclear Chemistry
Published
2024-09-09
DOI
https://doi.org/10.1007/s10967-024-09729-7
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration of a gamma ray Compton camera for radioactivity measurements

Huaiyu H. Chen‐Mayer, David Goodman, Bryan Remley, Steven Brown et al.
Journal of Radioanalytical and Nuclear Chemistry
Medical Imaging Techniques and Applications
article

Calibration of a gamma ray Compton camera for radioactivity measurements

Huaiyu H. Chen‐Mayer, David Goodman, Bryan Remley, Steven Brown, Dağıstan Şahin
article en

Abstract

Abstract A dual-plane Compton imaging detector previously developed for prompt gamma imaging has been further tested and calibrated for quantitative radioactivity determination, specifically to assess radioactive debris from a reactor fuel element. The debris piece contains uranium isotopes and several long-lived fission products, including cesium-137 (Cs-137). The detector consists of two pixelated planes of cadmium-zinc-telluride (CZT) crystals which record gamma ray events interacting within these volumes. In addition to the energy spectrum obtained by pulse height analysis, the time-stamped events from each detector pixel are sorted by location into 3 categories for post-processing: intra-plane, inter-plane, and coincidence. An image reconstruction software enables spatial localization of the select gamma ray peak(s) from the spectrum, thereby separating the gamma ray by specific isotopes. We used the camera to image a small piece of debris for demonstration purposes. A measurement was performed alongside a high purity germanium (HPGe) detector, which could determine the isotopes' absolute activities and be used as a reference for the camera. In addition, a known isotopic point source was used to calibrate the camera’s energy detection efficiency in the same measurement geometry, correlating the image pixel intensity to the isotopic activity.

Journal of Radioanalytical and Nuclear ChemistryVol. 333(12)
National Institute of Standards and Technology (US), H3D (United States) (US)
Small Business Innovative Research and Small Business Technology Transfer
Openalex Percentile: Top 75%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Calibration of a gamma ray Compton camera for radioactivity measurements — Huaiyu H. Chen‐Mayer, David Goodman, et al. · Journal of Radioanalytical and Nuclear Chemistry (2024) | TGRS Research Map | TGRS