One‐Pot Carbothermal Reduction Preparation of Cu‐BTC@Cu/C Heterostructure for Enhanced Nonenzymatic Electrochemical Glucose Sensing

Abstract A heterostructure based on MOFs with a small lattice mismatch is ideal for improving glucose‘s electrochemical sensing performance. Herein, a novel one‐pot carbothermal reduction technique to prepare Cu‐BTC@Cu/C heterostructure with intimate interfacial contact and high yield was developed, by in situ integrating Cu‐BTC (Cu 3 (BTC) 2 ⋅ 3H 2 O) and its derived Cu/C nanocomposites. Structure characterizations demonstrated that Cu‐BTC@Cu/C heterostructure shows a synergistic effect in the combination of these two components, with more electrochemical active sites and lower resistance. Compared with each individual component, Cu‐BTC@Cu/C heterostructure exhibits better glucose electrooxidation performance. Under optimal condition, an extremely sensitive nonenzymatic glucose sensor with a low detection limit of 6.78 μM, sensitivity of 911.03 μA mM −1 cm −2 , linear range of 0.001–2.0 mM, and anti‐interference performance is presented. Meanwhile, the newly constructed sensor was effectively employed for detecting glucose in honey sample with perfect recoveries, showing its great potential toward glucose monitoring in real sample. In addition, it has been demonstrated Cu(II) can be induced into Cu(I) by glucose in solution, while Cu(I) could be electrochemically converted to Cu(II), therefore achieving a Cu(I)/Cu(II) redox cycle. It offers a promising strategy for synthesis of advanced electrocatalysts with high efficiency and promising applications in this paper.

Authors

Institutions

Publication Details

Journal
ChemistrySelect
Published
2024-09-09
DOI
https://doi.org/10.1002/slct.202402198
Citations
2
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One‐Pot Carbothermal Reduction Preparation of Cu‐BTC@Cu/C Heterostructure for Enhanced Nonenzymatic Electrochemical Glucose Sensing

Xinghui Hou, Quanli Jia, Junyan Cui, Huiyu Yuan et al.
2 citations
ChemistrySelect
Electrochemical sensors and biosensors
0.42
article

One‐Pot Carbothermal Reduction Preparation of Cu‐BTC@Cu/C Heterostructure for Enhanced Nonenzymatic Electrochemical Glucose Sensing

Xinghui Hou, Quanli Jia, Junyan Cui, Huiyu Yuan, Niu Yao, Kai Liang
article en
2 citations

Abstract

Abstract A heterostructure based on MOFs with a small lattice mismatch is ideal for improving glucose‘s electrochemical sensing performance. Herein, a novel one‐pot carbothermal reduction technique to prepare Cu‐BTC@Cu/C heterostructure with intimate interfacial contact and high yield was developed, by in situ integrating Cu‐BTC (Cu 3 (BTC) 2 ⋅ 3H 2 O) and its derived Cu/C nanocomposites. Structure characterizations demonstrated that Cu‐BTC@Cu/C heterostructure shows a synergistic effect in the combination of these two components, with more electrochemical active sites and lower resistance. Compared with each individual component, Cu‐BTC@Cu/C heterostructure exhibits better glucose electrooxidation performance. Under optimal condition, an extremely sensitive nonenzymatic glucose sensor with a low detection limit of 6.78 μM, sensitivity of 911.03 μA mM −1 cm −2 , linear range of 0.001–2.0 mM, and anti‐interference performance is presented. Meanwhile, the newly constructed sensor was effectively employed for detecting glucose in honey sample with perfect recoveries, showing its great potential toward glucose monitoring in real sample. In addition, it has been demonstrated Cu(II) can be induced into Cu(I) by glucose in solution, while Cu(I) could be electrochemically converted to Cu(II), therefore achieving a Cu(I)/Cu(II) redox cycle. It offers a promising strategy for synthesis of advanced electrocatalysts with high efficiency and promising applications in this paper.

ChemistrySelectVol. 9(34)
Zhengzhou University (CN), Shandong Institute for Product Quality Inspection (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 38%
Electrochemical sensors and biosensors
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.