A Novel Method for Estimating the Thermal Performance of Multi-Block Wall Systems Using Thermal Impedance Z-Value under Transient Uncontrolled Heat Transfer Conditions

Climate change is one of the biggest challenges today. An increasing population accelerates the construction of concrete houses and the use of air conditioners, thereby leading to an increase in energy consumption. When the walls of buildings are well-designed and insulated, energy consumption can be reduced. Therefore, it is important to measure the thermal performance of wall systems accurately. The existing traditional methods of measuring R- and U-values provide acceptable solutions for steady-state controlled, uncontrolled or transient state-controlled conditions. However, a need to develop a novel approach for transient state-uncontrolled realistic conditions has been identified. The present study involves both experimental and numerical investigations. An in situ model room with dimensions of 1.60 m × 1.73 m × 1.50 m was built for the experimental work, and a series of experiments were conducted. For numerical work, two models using Ansys Fluent 2021/2022 and MATLAB Simulink 2021/2022 were developed. The real-time experimental data were fed into numerical models to predict the thermal behavior of the wall system. The results include the evaluation of a concept called ‘Time-Lag’ for all three models. ‘Time-Lag’ is the time taken for the heat energy to flow across the wall system. The Time-Lag for the experimental model was 8 h 45 min, while for MATLAB and Ansys models, it was 8 h 22 min. (average) and 7 h 30 min, respectively. Minor variations validate the accuracy of the numerical models. Further, a novel method using a new parameter in building systems called ‘thermal impedance Z-value’ was developed to estimate the real-time thermal performance of walls using MATLAB Simulink. The Z-value measures the ability of a wall system to resist the flow of heat (thermal resistance, R-value) combined with its ability to store heat energy (thermal capacitance, Cth-value). It is evaluated for steady-state and dynamic (transient) systems. For the steady-state system, the Z-values on the outer and inner walls were 18.2683 K/W and 18.6761 K/W, respectively with a minor difference of 0.4078 K/W at the end of 72 h. For the dynamic system, the Z-value did not reach a constant value and fluctuated in a particular pattern during 24 h of the solar cycle with average values of 3.2969 K/W on the outer and 1.2886 K/W on the inner walls at the end of 72 h, thus presenting more accurate and realistic thermal performance results of a wall system.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-09-09
DOI
https://doi.org/10.3390/buildings14092833
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Method for Estimating the Thermal Performance of Multi-Block Wall Systems Using Thermal Impedance Z-Value under Transient Uncontrolled Heat Transfer Conditions

Yousif Abdalla Abakr, Payal Ashish Modi, Abdelgadir Mahmoud, Bu Kwan Kee
Buildings
Building Energy and Comfort Optimization
article

A Novel Method for Estimating the Thermal Performance of Multi-Block Wall Systems Using Thermal Impedance Z-Value under Transient Uncontrolled Heat Transfer Conditions

Yousif Abdalla Abakr, Payal Ashish Modi, Abdelgadir Mahmoud, Bu Kwan Kee
article en

Abstract

Climate change is one of the biggest challenges today. An increasing population accelerates the construction of concrete houses and the use of air conditioners, thereby leading to an increase in energy consumption. When the walls of buildings are well-designed and insulated, energy consumption can be reduced. Therefore, it is important to measure the thermal performance of wall systems accurately. The existing traditional methods of measuring R- and U-values provide acceptable solutions for steady-state controlled, uncontrolled or transient state-controlled conditions. However, a need to develop a novel approach for transient state-uncontrolled realistic conditions has been identified. The present study involves both experimental and numerical investigations. An in situ model room with dimensions of 1.60 m × 1.73 m × 1.50 m was built for the experimental work, and a series of experiments were conducted. For numerical work, two models using Ansys Fluent 2021/2022 and MATLAB Simulink 2021/2022 were developed. The real-time experimental data were fed into numerical models to predict the thermal behavior of the wall system. The results include the evaluation of a concept called ‘Time-Lag’ for all three models. ‘Time-Lag’ is the time taken for the heat energy to flow across the wall system. The Time-Lag for the experimental model was 8 h 45 min, while for MATLAB and Ansys models, it was 8 h 22 min. (average) and 7 h 30 min, respectively. Minor variations validate the accuracy of the numerical models. Further, a novel method using a new parameter in building systems called ‘thermal impedance Z-value’ was developed to estimate the real-time thermal performance of walls using MATLAB Simulink. The Z-value measures the ability of a wall system to resist the flow of heat (thermal resistance, R-value) combined with its ability to store heat energy (thermal capacitance, Cth-value). It is evaluated for steady-state and dynamic (transient) systems. For the steady-state system, the Z-values on the outer and inner walls were 18.2683 K/W and 18.6761 K/W, respectively with a minor difference of 0.4078 K/W at the end of 72 h. For the dynamic system, the Z-value did not reach a constant value and fluctuated in a particular pattern during 24 h of the solar cycle with average values of 3.2969 K/W on the outer and 1.2886 K/W on the inner walls at the end of 72 h, thus presenting more accurate and realistic thermal performance results of a wall system.

BuildingsVol. 14(9)
University of Nottingham Malaysia Campus (MY), Universiti Tun Abdul Razak (MY)
Openalex Percentile: Top 85%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.