The Effect of K3EDTA Blood Volume Variation on Complete Blood Count Results

This study aims to determine the effect of varying K3EDTA blood volumes on complete blood count (CBC) results. Venous blood collection was performed using a closed system method. Blood was collected into K3EDTA vacutainer tubes with varying volumes of 1 mL, 2 mL, and 3 mL for each respondent, with a total of 10 respondents. The CBC parameters examined were WBC, RBC, Hb, Hct, MCV, MCH, MCHC, and PLT, using a quality-controlled hematology analyzer. Normally distributed data were analyzed using ANOVA, while non-normally distributed data were analyzed using the Friedman test. The results showed p-values > 0.05 for WBC, RBC, Hb, Hct, MCV, MCH, and MCHC, whereas the PLT test results showed a p-value < 0.05. The conclusion of this study is that there is an effect of varying K3EDTA blood volumes on PLT test results, but no effect on WBC, RBC, Hb, Hct, MCV, MCH, and MCHC test results.

Authors

Institutions

Publication Details

Journal
Formosa Journal of Science and Technology
Published
2024-08-15
DOI
https://doi.org/10.55927/fjst.v3i8.10103
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of K3EDTA Blood Volume Variation on Complete Blood Count Results

Rifky Saldi A. Wahid, Maya Tamara Mawardani, La Ode Marsudi, Rinda Aulia Utami
Formosa Journal of Science and Technology
Hemodynamic Monitoring and Therapy
article

The Effect of K3EDTA Blood Volume Variation on Complete Blood Count Results

Rifky Saldi A. Wahid, Maya Tamara Mawardani, La Ode Marsudi, Rinda Aulia Utami
article en

Abstract

This study aims to determine the effect of varying K3EDTA blood volumes on complete blood count (CBC) results. Venous blood collection was performed using a closed system method. Blood was collected into K3EDTA vacutainer tubes with varying volumes of 1 mL, 2 mL, and 3 mL for each respondent, with a total of 10 respondents. The CBC parameters examined were WBC, RBC, Hb, Hct, MCV, MCH, MCHC, and PLT, using a quality-controlled hematology analyzer. Normally distributed data were analyzed using ANOVA, while non-normally distributed data were analyzed using the Friedman test. The results showed p-values > 0.05 for WBC, RBC, Hb, Hct, MCV, MCH, and MCHC, whereas the PLT test results showed a p-value < 0.05. The conclusion of this study is that there is an effect of varying K3EDTA blood volumes on PLT test results, but no effect on WBC, RBC, Hb, Hct, MCV, MCH, and MCHC test results.

Formosa Journal of Science and TechnologyVol. 3(8)
Institut Ilmu Kesehatan Bhakti Wiyata (ID)
Openalex Percentile: Top 72%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Effect of K3EDTA Blood Volume Variation on Complete Blood Count Results — Rifky Saldi A. Wahid, Maya Tamara Mawardani, et al. · Formosa Journal of Science and Technology (2024) | TGRS Research Map | TGRS