Effect of Triton X-100 surfactant and agitation on tetramethylammonium hydroxide wet etching for microneedle fabrication

Solid silicon (Si) microneedles have many applications such as skin pretreatment to form micrometer-sized holes in the skin surface in transdermal drug delivery systems. Wet etching based on tetramethylammonium hydroxide (TMAH) is an efficient method to fabricate solid microneedles. However, it is challenging to increase the density of microneedle arrays due to the faster lateral etching than the vertical etching that requires a large initial mask size. In this work, we used wet etching based on TMAH to fabricate solid Si microneedles. One kind of nonionic surfactant, Triton X-100, was introduced into the TMAH solution to suppress the lateral etching. When Triton X-100 was added into TMAH for a given etching condition, the maximum height (attained right before the mask fell off) of microneedles could reach ∼230 μm for 600 μm square-shaped mask size and 700 μm array period, compared to microneedles of maximum 152 μm height for the same mask size and period without surfactant addition. Correspondingly, when the target heights of microneedles were the same as ∼230 μm, denser (down to 700 μm period, 600 μm mask size) microneedle arrays were achieved with the help of Triton X-100, in comparison to arrays down to 900 μm period (800 μm mask size) without surfactant addition. Furthermore, agitation by a magnetic stirring bar is important for the fabrication of dense solid Si microneedle arrays based on TMAH. The microneedle structures were rhombic pyramid in shape with Triton X-100 and agitation. But microneedle structures obtained with Triton X-100 yet without agitation were octagonal pyramid in shape with a much less steep side surface.

Authors

Institutions

Publication Details

Journal
Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics Materials Processing Measurement and Phenomena
Published
2024-09-01
DOI
https://doi.org/10.1116/6.0003852
Citations
1
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Triton X-100 surfactant and agitation on tetramethylammonium hydroxide wet etching for microneedle fabrication

Wenhan Hu, Bo Cui, Yu He
1 citations
Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics Materials Processing Measurement and Phenomena
Advancements in Transdermal Drug Delivery
0.21
article

Effect of Triton X-100 surfactant and agitation on tetramethylammonium hydroxide wet etching for microneedle fabrication

Wenhan Hu, Bo Cui, Yu He
article en
1 citations

Abstract

Solid silicon (Si) microneedles have many applications such as skin pretreatment to form micrometer-sized holes in the skin surface in transdermal drug delivery systems. Wet etching based on tetramethylammonium hydroxide (TMAH) is an efficient method to fabricate solid microneedles. However, it is challenging to increase the density of microneedle arrays due to the faster lateral etching than the vertical etching that requires a large initial mask size. In this work, we used wet etching based on TMAH to fabricate solid Si microneedles. One kind of nonionic surfactant, Triton X-100, was introduced into the TMAH solution to suppress the lateral etching. When Triton X-100 was added into TMAH for a given etching condition, the maximum height (attained right before the mask fell off) of microneedles could reach ∼230 μm for 600 μm square-shaped mask size and 700 μm array period, compared to microneedles of maximum 152 μm height for the same mask size and period without surfactant addition. Correspondingly, when the target heights of microneedles were the same as ∼230 μm, denser (down to 700 μm period, 600 μm mask size) microneedle arrays were achieved with the help of Triton X-100, in comparison to arrays down to 900 μm period (800 μm mask size) without surfactant addition. Furthermore, agitation by a magnetic stirring bar is important for the fabrication of dense solid Si microneedle arrays based on TMAH. The microneedle structures were rhombic pyramid in shape with Triton X-100 and agitation. But microneedle structures obtained with Triton X-100 yet without agitation were octagonal pyramid in shape with a much less steep side surface.

Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics Materials Processing Measurement and PhenomenaVol. 42(5)
Shanghai University (CN), University of Waterloo (CA)
Openalex Percentile: Top 51%
Advancements in Transdermal Drug Delivery
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.