Extrapolative Validity Evidence of the Anastomosis Objective Structured Assessment of Technical Skill (A-OSATS) for Robotic Ileocolic Anastomosis
We provide extrapolative validity evidence for the A-OSATS instrument by comparing A-OSATS score to time to sew, provocative leak test, and discrimination between PGY-4s and PGY-5s. Generalizability validity evidence is provided by test-retest reliability. Further refinement is needed for the A-OSATS tool to be used for high-stakes entrustment decisions in resident-performed robotic ileocolic anastomoses.
Authors
- Kerri A. Ohman (ORCID: https://orcid.org/0000-0001-7637-7339)
- Paul E. Wise (ORCID: https://orcid.org/0000-0003-3798-7913)
- Tiffany K Brocke (ORCID: https://orcid.org/0009-0009-4099-3733)
- Michael M. Awad (ORCID: https://orcid.org/0000-0002-6065-7050)
- Coen Klos
- Julie M. Clanahan (ORCID: https://orcid.org/0000-0002-9103-3152)
- William C. Chapman (ORCID: https://orcid.org/0000-0002-0072-3239)
- Cory Fox
Institutions
- Washington University in St. Louis (US)
- John Cochran VA Medical Center (US)
Publication Details
- Journal
- Journal of surgical education
- Published
- 2024-09-09
- DOI
- https://doi.org/10.1016/j.jsurg.2024.07.021
- Citations
- 2
- Primary Topic
- Surgical Simulation and Training
- Type
- article
- Field-Weighted Citation Impact
- 1.15
Funders
- Intuitive Surgical