Design and application of a high-precision counterweighted self-calibrating surface thermometer

In this study, a high-precision counterweight self-calibrating surface thermometer is designed to reduce human and environmental influences on a thermocouple surface thermometer during measuring. A self-weighted spring structure based on a copper substrate is designed to ensure perfect contact between the surface thermometer and the temperature source. In conjunction, a wind guard is coupled with insulating materials to optimize the thermal exchange of the surface thermometer. Subsequently, the maximum error is reduced to ±1.5 °C by system hardware optimization. However, hardware calibration alone is insufficient. Furthermore, a back propagation neural network is employed to calibrate the surface thermometer. Temperature sensor data are collected under various surface source temperatures and airflow velocities to train the neural network. Hence, the effectiveness of the proposed Gaussian function in enhancing the measurement accuracy of the surface temperature sensor is demonstrated. The results show higher stability and repeatability in temperature measurement than thermocouple-based surface thermometers. The proposed thermometer exhibits robustness against environmental and operational variability with a maximum indication error of -0.2 °C. In contrast, the maximum error of the surface thermometer is between -2.8 and -6.8 °C. Regarding repeatability, the standard deviation with the proposed device is 0.2%, highlighting its accuracy and consistency of performance. These results can mostly be attributed to the synergistic effect of clever mechanical design and software optimization, resulting in a surface thermometer with outstanding accuracy and repeatability.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-09-01
DOI
https://doi.org/10.1063/5.0225510
Citations
1
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
1.30

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and application of a high-precision counterweighted self-calibrating surface thermometer

Sijun Huang, Qiuquan Zhang, Xianjie Liu, Li Feng et al.
1 citations
Review of Scientific Instruments
Calibration and Measurement Techniques
1.30
article

Design and application of a high-precision counterweighted self-calibrating surface thermometer

Sijun Huang, Qiuquan Zhang, Xianjie Liu, Li Feng, Xiaolin Wang, Daidong Chen
article en
1 citations

Abstract

In this study, a high-precision counterweight self-calibrating surface thermometer is designed to reduce human and environmental influences on a thermocouple surface thermometer during measuring. A self-weighted spring structure based on a copper substrate is designed to ensure perfect contact between the surface thermometer and the temperature source. In conjunction, a wind guard is coupled with insulating materials to optimize the thermal exchange of the surface thermometer. Subsequently, the maximum error is reduced to ±1.5 °C by system hardware optimization. However, hardware calibration alone is insufficient. Furthermore, a back propagation neural network is employed to calibrate the surface thermometer. Temperature sensor data are collected under various surface source temperatures and airflow velocities to train the neural network. Hence, the effectiveness of the proposed Gaussian function in enhancing the measurement accuracy of the surface temperature sensor is demonstrated. The results show higher stability and repeatability in temperature measurement than thermocouple-based surface thermometers. The proposed thermometer exhibits robustness against environmental and operational variability with a maximum indication error of -0.2 °C. In contrast, the maximum error of the surface thermometer is between -2.8 and -6.8 °C. Regarding repeatability, the standard deviation with the proposed device is 0.2%, highlighting its accuracy and consistency of performance. These results can mostly be attributed to the synergistic effect of clever mechanical design and software optimization, resulting in a surface thermometer with outstanding accuracy and repeatability.

Review of Scientific InstrumentsVol. 95(9)
Chongqing Metrology Quality Inspection and Research Institute (CN)
Chongqing Basic and Frontier Research Project
Affordable and clean energy
Openalex Percentile: Top 13%
Calibration and Measurement Techniques
1.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.