Rapid calibration plan for NIF’s Near Backscatter Imager (NBI)

A rapid calibration system is under development for the Near Backscatter Imager (NBI) in use at the National Ignition Facility (NIF). NBI is an optical diagnostic that quantifies the stimulated Brillouin and Raman backscatter produced by NIF's targets. Specifically, NBI measures the light that does not fall directly back into the laser aperture, which is measured by the Full Aperture Backscatter System (FABS). When working in tandem with FABS, NBI allows for the full characterization of backscattered light. This informs Hohlraum laser coupling, optical damage, and laser-plasma interaction models. NBI uses a large Spectralon plate covered by a protective glass layer and is mounted inside the target chamber where it is exposed to high energy backscatter, neutrons, and build-up debris left over from the exploded targets. This gradually alters the reflectivity of the plate, meaning that NBI needs to be calibrated regularly. Described here is NIF's design for a system capable of rapid in situ calibration of NBI that is to be installed in FY25.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-09-01
DOI
https://doi.org/10.1063/5.0219559
Citations
1
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid calibration plan for NIF’s Near Backscatter Imager (NBI)

N. Lemos, George F. Swadling, Henry J. Meyer, Eleanor Tubman et al.
1 citations
Review of Scientific Instruments
Laser-Plasma Interactions and Diagnostics
0.66
article

Rapid calibration plan for NIF’s Near Backscatter Imager (NBI)

N. Lemos, George F. Swadling, Henry J. Meyer, Eleanor Tubman, C. Bruulsema, J. S. Ross, J. D. Moody
article en
1 citations

Abstract

A rapid calibration system is under development for the Near Backscatter Imager (NBI) in use at the National Ignition Facility (NIF). NBI is an optical diagnostic that quantifies the stimulated Brillouin and Raman backscatter produced by NIF's targets. Specifically, NBI measures the light that does not fall directly back into the laser aperture, which is measured by the Full Aperture Backscatter System (FABS). When working in tandem with FABS, NBI allows for the full characterization of backscattered light. This informs Hohlraum laser coupling, optical damage, and laser-plasma interaction models. NBI uses a large Spectralon plate covered by a protective glass layer and is mounted inside the target chamber where it is exposed to high energy backscatter, neutrons, and build-up debris left over from the exploded targets. This gradually alters the reflectivity of the plate, meaning that NBI needs to be calibrated regularly. Described here is NIF's design for a system capable of rapid in situ calibration of NBI that is to be installed in FY25.

Review of Scientific InstrumentsVol. 95(9)
Lawrence Livermore National Laboratory (US), Imperial College London (GB)
Lawrence Livermore National Laboratory
Openalex Percentile: Top 15%
Laser-Plasma Interactions and Diagnostics
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Rapid calibration plan for NIF’s Near Backscatter Imager (NBI) — N. Lemos, George F. Swadling, et al. · Review of Scientific Instruments (2024) | TGRS Research Map | TGRS