Determination of the optimal number of detectors for the multiangle wire beam scanning method

Abstract The implementation of control over the characteristics of the beam is an important stage in the conduct of experiments within the field of accelerator physics. The multiangle scanning method based on the reconstruction of the electron beam profile image from projection data can be used to determine the distribution of beam intensities in the transverse plane. In order to reduce the time required for measurement, it is proposed that a set of detecting elements be used in place of a single detecting element when employing this method. This work presents a scheme for optimized data collection using the multiangle scanning method and evaluates the applicability of the modernized approach. For this, a numerical experiment was conducted to determine the beam profile using different numbers of detecting elements. The results of this study demonstrate that the use of multiple detecting elements for the implementation of the multiangle scanning method reduces the measurement time and ensures high quality of the reconstructed beam profile images. It was demonstrated that the minimum number of detecting elements necessary to ascertain a specific beam profile is ten.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-09-01
DOI
https://doi.org/10.1088/1748-0221/19/09/c09002
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the optimal number of detectors for the multiangle wire beam scanning method

I. Miloichikova, Maria Banshchikova, A. Bulavskaya, S. Stuchebrov et al.
2 citations
Journal of Instrumentation
Medical Imaging Techniques and Applications
0.81
article

Determination of the optimal number of detectors for the multiangle wire beam scanning method

I. Miloichikova, Maria Banshchikova, A. Bulavskaya, S. Stuchebrov, A. Grigorieva
article en
2 citations

Abstract

Abstract The implementation of control over the characteristics of the beam is an important stage in the conduct of experiments within the field of accelerator physics. The multiangle scanning method based on the reconstruction of the electron beam profile image from projection data can be used to determine the distribution of beam intensities in the transverse plane. In order to reduce the time required for measurement, it is proposed that a set of detecting elements be used in place of a single detecting element when employing this method. This work presents a scheme for optimized data collection using the multiangle scanning method and evaluates the applicability of the modernized approach. For this, a numerical experiment was conducted to determine the beam profile using different numbers of detecting elements. The results of this study demonstrate that the use of multiple detecting elements for the implementation of the multiangle scanning method reduces the measurement time and ensures high quality of the reconstructed beam profile images. It was demonstrated that the minimum number of detecting elements necessary to ascertain a specific beam profile is ten.

Journal of InstrumentationVol. 19(09)
Russian Academy of Sciences (RU), National Research Tomsk State University (RU), Tomsk Polytechnic University (RU), Tomsk National Research Medical Center (RU)
Openalex Percentile: Top 26%
Medical Imaging Techniques and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.