Preparation & characterization of polyvinyl alcohol/thymol blue composites gel and films for low radiation dosimetry

Exposure to low radiation has been indispensable due to it is necessity in radiography and it is induced potential effects in patients and radiology staff. Hence the measurement and detection became inevitable for radiation practitioners and the patients. The study aimed to present the synthesis of polyvinyl alcohol gel doped with Thymol Blue dye (PVA/TB) as gel and films for low radiation dosimetry. The polymer was prepared under controlled parameters (PVA 5%, temperature 80 °C, dopped with 0.01, 0.03, 0.05, 0.07, 0.09 mw of TB). The formed gel and films were irradiated with x-ray as: 0, 2, 4, 6, 8, 10 mGy. Gel and films showed color quenching from yellow to light yellow as the radiation dose increased, as well as gradual significant (R 2 = 0.97) reduction in optical density for all concentration (0.01, 0.02–0.09 mw of TB). The UV-spectroscope for (PVA/TB 0.01mw ) gel showed absorbance peaks at λ = 435, 326 and 279 nm, that decreased significantly (R 2 = 0.97) as the radiation dose increases. And XRD for (PVA/TB 0.01 mw ) reveals the crystallinity of PVA at 2 thetas = 19.5° which increased to 40.5% at 10 mGy. FTIR revealed the chemical bonds with relevant intensities (CH (725.1–781 & 3030 cm −1 ), C – C (883.2 & 1170.6 cm −1 ), C – O (1063- 1096 cm −1 ), CH 2 (1357.6 cm −1 wagging, 2879.2 cm −1 alkyl stretch), C = C (1623.8–1651.5 cm −1 ), C = O (1681.6–1683.6 cm −1 ), C – OH (3288 cm −1 )) that decreased as the radiation dose increased and new radiogenic bonds at vibrational bands 1063–1096 cm −1 referring to C – O – C of Polysaccharide's pyranose and at 2125.1 cm −1 for C ≡ C alkenyl). Both forms of PVA/TB films and gel showed feasibility and applicability for radiation detection and measurement.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research and Applied Sciences
Published
2024-09-09
DOI
https://doi.org/10.1016/j.jrras.2024.101103
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation & characterization of polyvinyl alcohol/thymol blue composites gel and films for low radiation dosimetry

Abdalla Abdelkarem Abdalla, Mohammed A. Ali Omer
1 citations
Journal of Radiation Research and Applied Sciences
Advanced Radiotherapy Techniques
0.61
article

Preparation & characterization of polyvinyl alcohol/thymol blue composites gel and films for low radiation dosimetry

Abdalla Abdelkarem Abdalla, Mohammed A. Ali Omer
article en
1 citations

Abstract

Exposure to low radiation has been indispensable due to it is necessity in radiography and it is induced potential effects in patients and radiology staff. Hence the measurement and detection became inevitable for radiation practitioners and the patients. The study aimed to present the synthesis of polyvinyl alcohol gel doped with Thymol Blue dye (PVA/TB) as gel and films for low radiation dosimetry. The polymer was prepared under controlled parameters (PVA 5%, temperature 80 °C, dopped with 0.01, 0.03, 0.05, 0.07, 0.09 mw of TB). The formed gel and films were irradiated with x-ray as: 0, 2, 4, 6, 8, 10 mGy. Gel and films showed color quenching from yellow to light yellow as the radiation dose increased, as well as gradual significant (R 2 = 0.97) reduction in optical density for all concentration (0.01, 0.02–0.09 mw of TB). The UV-spectroscope for (PVA/TB 0.01mw ) gel showed absorbance peaks at λ = 435, 326 and 279 nm, that decreased significantly (R 2 = 0.97) as the radiation dose increases. And XRD for (PVA/TB 0.01 mw ) reveals the crystallinity of PVA at 2 thetas = 19.5° which increased to 40.5% at 10 mGy. FTIR revealed the chemical bonds with relevant intensities (CH (725.1–781 & 3030 cm −1 ), C – C (883.2 & 1170.6 cm −1 ), C – O (1063- 1096 cm −1 ), CH 2 (1357.6 cm −1 wagging, 2879.2 cm −1 alkyl stretch), C = C (1623.8–1651.5 cm −1 ), C = O (1681.6–1683.6 cm −1 ), C – OH (3288 cm −1 )) that decreased as the radiation dose increased and new radiogenic bonds at vibrational bands 1063–1096 cm −1 referring to C – O – C of Polysaccharide's pyranose and at 2125.1 cm −1 for C ≡ C alkenyl). Both forms of PVA/TB films and gel showed feasibility and applicability for radiation detection and measurement.

Journal of Radiation Research and Applied SciencesVol. 17(4)
University of Medical Sciences and Technology (SD), Qassim University (SA), Sudan University of Science and Technology (SD)
Openalex Percentile: Top 32%
Advanced Radiotherapy Techniques
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.