Parabolic mirror cavity-enhanced Raman spectroscopy for trace gas detection

A parabolic mirror cavity-enhanced Raman spectroscopy (PM-CERS) method was reported, utilizing a combined optical path of a parabolic mirror and a multi-pass cell. In this setup, the focal point of the parabolic mirror is aligned with the laser convergence center of the multi-pass cell. This method achieved high excitation intensity at the focal point and broadened the collection range of Raman scattering signals, thus significantly improving both the excitation and collection efficiency of Raman signals. Additionally, the structure of the system was simplified through the integrated design of the collection cavity and sample cell. Nitrogen, oxygen, water vapor, and carbon dioxide could be detected in the air within an exposure time of just 0.5 s, achieving the limits of detection at the ppm level. Compared to the conventional multi-pass cell, the signal intensity and signal-to-noise ratio were each enhanced by approximately 5.6-fold, further demonstrating the excellent potential application in trace gas detection.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2024-09-09
DOI
https://doi.org/10.1364/ol.534842
Citations
9
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
5.96
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parabolic mirror cavity-enhanced Raman spectroscopy for trace gas detection

Zhiqiang Ning, Ying Pan, Yonghua Fang, Zhengang Li et al.
9 citations
Optics Letters
Spectroscopy Techniques in Biomedical and Chemical Research
5.96
article

Parabolic mirror cavity-enhanced Raman spectroscopy for trace gas detection

Zhiqiang Ning, Ying Pan, Yonghua Fang, Zhengang Li, Jiaxiang Liu, Haichun Xu, Junfang Miao
article en
9 citations

Abstract

A parabolic mirror cavity-enhanced Raman spectroscopy (PM-CERS) method was reported, utilizing a combined optical path of a parabolic mirror and a multi-pass cell. In this setup, the focal point of the parabolic mirror is aligned with the laser convergence center of the multi-pass cell. This method achieved high excitation intensity at the focal point and broadened the collection range of Raman scattering signals, thus significantly improving both the excitation and collection efficiency of Raman signals. Additionally, the structure of the system was simplified through the integrated design of the collection cavity and sample cell. Nitrogen, oxygen, water vapor, and carbon dioxide could be detected in the air within an exposure time of just 0.5 s, achieving the limits of detection at the ppm level. Compared to the conventional multi-pass cell, the signal intensity and signal-to-noise ratio were each enhanced by approximately 5.6-fold, further demonstrating the excellent potential application in trace gas detection.

Optics LettersVol. 49(19)
University of Science and Technology of China (CN), Anhui Institute of Optics and Fine Mechanics (CN)
Openalex Percentile: Top 4%
Spectroscopy Techniques in Biomedical and Chemical Research
5.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Parabolic mirror cavity-enhanced Raman spectroscopy for trace gas detection — Zhiqiang Ning, Ying Pan, et al. · Optics Letters (2024) | TGRS Research Map | TGRS