OP02.01: Artificial intelligence for automated Carnegie staging of the human embryo in three‐dimensional ultrasound: the Rotterdam periconception cohort

The Carnegie staging system facilitates the assessment of normal and abnormal development in terms of morphology during the embryonic period. Using virtual reality (VR) it is possible to visually assess the Carnegie stage in-utero, which takes 1-2 minutes per ultrasound image. Adoption in clinical practice is hampered by the need for a VR set-up and required time for visual assessment. To overcome this, our aim is to automate in-utero Carnegie staging using Artificial Intelligence (AI). 1357 first trimester three-dimensional (3D) ultrasound images of 797 ongoing pregnancies resulting in life birth from The Rotterdam Periconception Cohort were used. We used DenseNet, a state-of-the-art deep learning algorithm for image classification. The algorithm was trained to estimate the Carnegie stage < 16, 16-23, and 23> solely based on the ultrasound images. We used 1100 images of 642 pregnancies for training. For evaluation, we used a test set of 257 images of 155 pregnancies, not used during training. The AI algorithm achieved an overall accuracy of 61%, which is close to the results of an independent rater, who achieved an accuracy of 63% on 46 images selected for manual VR assessment training. The accuracy was for stage < 16: 55% (n = 9), for stages 16-19: 59% (n = 79), for stages 20-23:62% (n = 151), and for stage >23: 61% (n = 18). The performance differences can partly be explained by the limited size of the embryo early in the first trimester. Since automatic Carnegie staging using AI is real-time and does not require a VR set-up adoption in clinical practice becomes feasible. In future work, we aim to enhance interpretability by analysing the specific morphological aspects in ultrasound scans utilised by the algorithm to assign the Carnegie stage. Understanding the morphological aspects linked to the Carnegie stage by the algorithm might lead to more in-depth insight into the patterns of normal and abnormal morphological development across pregnancies.

Authors

Institutions

Publication Details

Journal
Ultrasound in Obstetrics and Gynecology
Published
2024-09-01
DOI
https://doi.org/10.1002/uog.27883
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

OP02.01: Artificial intelligence for automated Carnegie staging of the human embryo in three‐dimensional ultrasound: the Rotterdam periconception cohort

W. Bastiaansen, Régine P.M. Steegers‐Theunissen, Melek Rousian, Stefan Klein et al.
Ultrasound in Obstetrics and Gynecology
Ultrasound Imaging and Elastography
article

OP02.01: Artificial intelligence for automated Carnegie staging of the human embryo in three‐dimensional ultrasound: the Rotterdam periconception cohort

W. Bastiaansen, Régine P.M. Steegers‐Theunissen, Melek Rousian, Stefan Klein, Ruben Niemantsverdriet, Franciscus M. Vos
article en

Abstract

The Carnegie staging system facilitates the assessment of normal and abnormal development in terms of morphology during the embryonic period. Using virtual reality (VR) it is possible to visually assess the Carnegie stage in-utero, which takes 1-2 minutes per ultrasound image. Adoption in clinical practice is hampered by the need for a VR set-up and required time for visual assessment. To overcome this, our aim is to automate in-utero Carnegie staging using Artificial Intelligence (AI). 1357 first trimester three-dimensional (3D) ultrasound images of 797 ongoing pregnancies resulting in life birth from The Rotterdam Periconception Cohort were used. We used DenseNet, a state-of-the-art deep learning algorithm for image classification. The algorithm was trained to estimate the Carnegie stage < 16, 16-23, and 23> solely based on the ultrasound images. We used 1100 images of 642 pregnancies for training. For evaluation, we used a test set of 257 images of 155 pregnancies, not used during training. The AI algorithm achieved an overall accuracy of 61%, which is close to the results of an independent rater, who achieved an accuracy of 63% on 46 images selected for manual VR assessment training. The accuracy was for stage < 16: 55% (n = 9), for stages 16-19: 59% (n = 79), for stages 20-23:62% (n = 151), and for stage >23: 61% (n = 18). The performance differences can partly be explained by the limited size of the embryo early in the first trimester. Since automatic Carnegie staging using AI is real-time and does not require a VR set-up adoption in clinical practice becomes feasible. In future work, we aim to enhance interpretability by analysing the specific morphological aspects in ultrasound scans utilised by the algorithm to assign the Carnegie stage. Understanding the morphological aspects linked to the Carnegie stage by the algorithm might lead to more in-depth insight into the patterns of normal and abnormal morphological development across pregnancies.

Ultrasound in Obstetrics and GynecologyVol. 64(S1)
Erasmus MC (NL), Erasmus University Rotterdam (NL), Delft University of Technology (NL)
Zero hunger
Openalex Percentile: Top 75%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.