EP09.51: Feasibility of fetal cardiac MRI in the prenatal evaluation of congenital heart defects in comparison to ultrasound

Congenital heart defects (CHD) are the most common severe birth defects. They are often life-threatening, resulting in a clinical need for precise prenatal assessment to provide best possible postnatal care. MRI of the fetal heart recently became feasible with the advent of novel gating techniques that allow for fetal cardiac rhythm monitoring within the scanner, but its feasibility has not yet been systematically evaluated in pregnancies with fetal CHD. We therefore assessed the value of fetal cardiac MRI in the prenatal management of these pregnancies. This case-control study yet evaluated 21 singleton pregnancies, consisting of 12 fetuses with diagnosis of CHD and 9 healthy control fetuses (HC). Diagnosis of CHD was refined by a cardiopediatrician. Subjects were referred to the MRI after US examination at 30 weeks onwards. All MRI images were reviewed by a single blinded operator also rating image quality of cardiac sequences from 0 (not usable) to 5 (high image quality). Correlation between MRI findings and US diagnosis was assessed. Fetal cardiac MRI was feasible in 19 out of 21 patients (91%; image quality score >0) due to fetal movement in n = 2 cases. Among, in n = 6 (31.6%), n = 10 (52.6%) and in n = 3 (15.8%) cases image quality was rated high (image quality score 5), medium (image quality score 3-4) and poor (image quality score 1-2), respectively. In the 12 fetuses with CHD, fetal cardiac MRI was capable to fully confirm US-diagnosis in n = 8 (66.7%) and partly in n = 4 (33.3%) cases, mostly due to incomplete recording of structures of interest. Agreement between MRI and US was good (κ-value 0.79 with an accuracy of 0.895). Our preliminary study suggests a similar performance of MRI and US. With improvements in sequences, gating techniques and operator experience, MRI examination could soon become an essential part of the prenatal management of CHD, not only to look for associated abnormalities but also to reinforce the assessment of heart disease itself.

Authors

Institutions

Publication Details

Journal
Ultrasound in Obstetrics and Gynecology
Published
2024-09-01
DOI
https://doi.org/10.1002/uog.28432
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EP09.51: Feasibility of fetal cardiac MRI in the prenatal evaluation of congenital heart defects in comparison to ultrasound

Sophia Stoecklein, Bertrand Stos, Gloria Biechele, D. Grévent et al.
1 links
Ultrasound in Obstetrics and Gynecology
Advanced MRI Techniques and Applications
article

EP09.51: Feasibility of fetal cardiac MRI in the prenatal evaluation of congenital heart defects in comparison to ultrasound

Sophia Stoecklein, Bertrand Stos, Gloria Biechele, D. Grévent, Daniéla Laux, Laurent Salomon
article en

Abstract

Congenital heart defects (CHD) are the most common severe birth defects. They are often life-threatening, resulting in a clinical need for precise prenatal assessment to provide best possible postnatal care. MRI of the fetal heart recently became feasible with the advent of novel gating techniques that allow for fetal cardiac rhythm monitoring within the scanner, but its feasibility has not yet been systematically evaluated in pregnancies with fetal CHD. We therefore assessed the value of fetal cardiac MRI in the prenatal management of these pregnancies. This case-control study yet evaluated 21 singleton pregnancies, consisting of 12 fetuses with diagnosis of CHD and 9 healthy control fetuses (HC). Diagnosis of CHD was refined by a cardiopediatrician. Subjects were referred to the MRI after US examination at 30 weeks onwards. All MRI images were reviewed by a single blinded operator also rating image quality of cardiac sequences from 0 (not usable) to 5 (high image quality). Correlation between MRI findings and US diagnosis was assessed. Fetal cardiac MRI was feasible in 19 out of 21 patients (91%; image quality score >0) due to fetal movement in n = 2 cases. Among, in n = 6 (31.6%), n = 10 (52.6%) and in n = 3 (15.8%) cases image quality was rated high (image quality score 5), medium (image quality score 3-4) and poor (image quality score 1-2), respectively. In the 12 fetuses with CHD, fetal cardiac MRI was capable to fully confirm US-diagnosis in n = 8 (66.7%) and partly in n = 4 (33.3%) cases, mostly due to incomplete recording of structures of interest. Agreement between MRI and US was good (κ-value 0.79 with an accuracy of 0.895). Our preliminary study suggests a similar performance of MRI and US. With improvements in sequences, gating techniques and operator experience, MRI examination could soon become an essential part of the prenatal management of CHD, not only to look for associated abnormalities but also to reinforce the assessment of heart disease itself.

Ultrasound in Obstetrics and GynecologyVol. 64(S1)
Université Paris Cité (FR), Institut Necker Enfants Malades (FR), Ludwig-Maximilians-Universität München (DE)
Zero hunger
Openalex Percentile: Top 75%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.