EP18.05: First trimester referral ultrasound following the introduction of the guidelines of the SIEOG: focus on false positives and false negatives

To analyse false positive and false negative diagnoses of first trimester referral US compared to second trimester referral US. Secondary analysis of a multicentre retrospective study of prospectively collected data including singleton pregnancies at risk for structural anomaly following 1st trimester screening US. The definition of “risk for structural anomaly” was based on either NT≥3.5mm or fetal structural anomalies suspected at 1st trimester US. Only cases undergoing referral 1st trimester US with a standardised protocol at one participating centres were included. The reference to evaluate the performance of 1st trimester US was represented by 2nd trimester referral US. 137 cases had paired referral US at 11+0-13+6 and at 19-21 weeks and 206 at 11+0-13+6 and 14-16 weeks. False negatives of 1st trimester US compared to 19-21 weeks' and 14-16 weeks' scan were 12 and 10, respectively. The former included minor cardiac anomalies (VSD, persistent LSVC), 1 case each of AVSD, ductus venous agenesis and fibular hemimelia and 4 cases of evolving anomalies (hydronephrosis, ACC, hydrops). The latter included 2 cases of major cardiac anomaly, 1 case of micrognathia and 1 case of fetal tail. False positives of 1st trimester referral US were recorded in 7 and 6 cases, respectively. These included 1 case of tetralogy of Fallot, 1 case of Blake's pouch cyst and 1 case of cleft lip. In the remaining 4 false positive cases of 1st trimester referral US evolving anomalies were recorded. Our data suggest a low rate of false positive and false negative diagnoses of 11+0-13+6 weeks' scan, the latter being most represented either by minor structural anomalies with little or no impact in terms of pre- and perinatal management and counselling or by evolving anomalies that cannot be diagnosed in the first trimester. Most of the false positive diagnoses are consistent with the natural history of the anomaly, even though over-diagnosis may be accounted as a limitation of first trimester referral ultrasound.

Authors

Institutions

Publication Details

Journal
Ultrasound in Obstetrics and Gynecology
Published
2024-09-01
DOI
https://doi.org/10.1002/uog.28742
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EP18.05: First trimester referral ultrasound following the introduction of the guidelines of the SIEOG: focus on false positives and false negatives

Tiziana Fanelli, G. Volpe, E. Corno, A. Dall’Asta et al.
Ultrasound in Obstetrics and Gynecology
Ultrasound in Clinical Applications
article

EP18.05: First trimester referral ultrasound following the introduction of the guidelines of the SIEOG: focus on false positives and false negatives

Tiziana Fanelli, G. Volpe, E. Corno, A. Dall’Asta, G. Minnella, Elisa Mantovani, Laura Sarno, Valentina D’Ambrosio, Paola Quaresima, Daniele Di Mascio, Ilaria Fantasia
article en

Abstract

To analyse false positive and false negative diagnoses of first trimester referral US compared to second trimester referral US. Secondary analysis of a multicentre retrospective study of prospectively collected data including singleton pregnancies at risk for structural anomaly following 1st trimester screening US. The definition of “risk for structural anomaly” was based on either NT≥3.5mm or fetal structural anomalies suspected at 1st trimester US. Only cases undergoing referral 1st trimester US with a standardised protocol at one participating centres were included. The reference to evaluate the performance of 1st trimester US was represented by 2nd trimester referral US. 137 cases had paired referral US at 11+0-13+6 and at 19-21 weeks and 206 at 11+0-13+6 and 14-16 weeks. False negatives of 1st trimester US compared to 19-21 weeks' and 14-16 weeks' scan were 12 and 10, respectively. The former included minor cardiac anomalies (VSD, persistent LSVC), 1 case each of AVSD, ductus venous agenesis and fibular hemimelia and 4 cases of evolving anomalies (hydronephrosis, ACC, hydrops). The latter included 2 cases of major cardiac anomaly, 1 case of micrognathia and 1 case of fetal tail. False positives of 1st trimester referral US were recorded in 7 and 6 cases, respectively. These included 1 case of tetralogy of Fallot, 1 case of Blake's pouch cyst and 1 case of cleft lip. In the remaining 4 false positive cases of 1st trimester referral US evolving anomalies were recorded. Our data suggest a low rate of false positive and false negative diagnoses of 11+0-13+6 weeks' scan, the latter being most represented either by minor structural anomalies with little or no impact in terms of pre- and perinatal management and counselling or by evolving anomalies that cannot be diagnosed in the first trimester. Most of the false positive diagnoses are consistent with the natural history of the anomaly, even though over-diagnosis may be accounted as a limitation of first trimester referral ultrasound.

Ultrasound in Obstetrics and GynecologyVol. 64(S1)
University of Parma (IT), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), Magna Graecia University (IT), Azienda Ospedaliera Universitaria Integrata Verona (IT), San Salvatore Hospital (IT), Azienda Ospedaliera Universitaria Policlinico "Paolo Giaccone" di Palermo (IT), University of Naples Federico II (IT), Sapienza University of Rome (IT)
Zero hunger
Openalex Percentile: Top 81%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.