EP08.08: Improving estimated fetal weight accuracy at a tertiary centre: a quality improvement intervention

Implementation of improvement strategies targeting identified error drivers of EFW identified by a quality assurance project in a tertiary healthcare centre in Canada. Based on previous reported quality improvement project at our centre, we proposed a lean goal of improving the error by 15% by sonographer education and incorporation of feedback. We audited our population 6 months after the intervention. 2 PDSA cycles were conducted. Images obtained within 14 days from delivery were analysed by independent examiner. The framework from 2019 ISUOG biometry guidelines scoring was used. Results were reported as descriptive statistics. Pre- and post-intervention were compared by T-test (P<.05). EFW error was found in 81 (5%) from 20% preintervention. When analysing images individually and comparing EFW parameters head-to-head for the scans with error, there were statistically significant improvements. Accurate EFW is critical for clinical decision-making and is a quality measure in antenatal care. Identifying key sonographic error drivers, education and feedback led to significant improvement.

Authors

Institutions

Publication Details

Journal
Ultrasound in Obstetrics and Gynecology
Published
2024-09-01
DOI
https://doi.org/10.1002/uog.28336
Primary Topic
Neonatal and fetal brain pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EP08.08: Improving estimated fetal weight accuracy at a tertiary centre: a quality improvement intervention

Layla Aiman Halawani, Ana Werlang, T. Zhang, Z. AlSomali
Ultrasound in Obstetrics and Gynecology
Neonatal and fetal brain pathology
article

EP08.08: Improving estimated fetal weight accuracy at a tertiary centre: a quality improvement intervention

Layla Aiman Halawani, Ana Werlang, T. Zhang, Z. AlSomali
article en

Abstract

Implementation of improvement strategies targeting identified error drivers of EFW identified by a quality assurance project in a tertiary healthcare centre in Canada. Based on previous reported quality improvement project at our centre, we proposed a lean goal of improving the error by 15% by sonographer education and incorporation of feedback. We audited our population 6 months after the intervention. 2 PDSA cycles were conducted. Images obtained within 14 days from delivery were analysed by independent examiner. The framework from 2019 ISUOG biometry guidelines scoring was used. Results were reported as descriptive statistics. Pre- and post-intervention were compared by T-test (P<.05). EFW error was found in 81 (5%) from 20% preintervention. When analysing images individually and comparing EFW parameters head-to-head for the scans with error, there were statistically significant improvements. Accurate EFW is critical for clinical decision-making and is a quality measure in antenatal care. Identifying key sonographic error drivers, education and feedback led to significant improvement.

Ultrasound in Obstetrics and GynecologyVol. 64(S1)
University of Ottawa (CA), Ottawa Hospital (CA), Ottawa Hospital Research Institute (CA)
Openalex Percentile: Top 76%
Neonatal and fetal brain pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

EP08.08: Improving estimated fetal weight accuracy at a tertiary centre: a quality improvement intervention — Layla Aiman Halawani, Ana Werlang, et al. · Ultrasound in Obstetrics and Gynecology (2024) | TGRS Research Map | TGRS