EP09.03: Transposition of great arteries: three‐dimensional virtual and physical models from obstetrical ultrasound data

A diabetic 34-year-old woman, gravida 2 para 1, was referred for fetal echocardiography evaluation. During the fetal echocardiogram (25 weeks of gestation), abnormal outflow tracts showing a parallel course of the great arteries raised a strong suspicion of simple transposition of great arteries (TGA). The diagnosis was subsequently confirmed by the anatomical characteristics of the arteries that arose from each ventricle. Fetal echocardiogram was performed using a 3D high-resolution probe (4–8-MHz transducer, Voluson E9, GE Healthcare, Zipf, Austria). For post-processing images, software 3D Slicer (Birmington, UK) and Elucis (Realize Medical, Ottawa, ON, Canada) enabled the correct segmentation and texture improvement of the 3D US image. Using the software Elucis, we could segment the fetal heart in a virtual reality (VR) after import the images obtained through 4D-STIC and insert them into the application platform. A 3D model of the fetal heart was printed using a resin 3D printer (J5 MediJet 3D Printer Stratasys, USA). The 3D physical and virtual models were used in this case as interesting additional diagnostic tools to the current standard imaging armamentarium, enabling us to improve the quality of prenatal parental counselling and to optimise of cardiac surgical planning. The male neonate was born by Caesarean section and the surgical correction of TGA (arterial switch) was performed. Currently, he is clinically well, and has a mild aortic insufficiency. Acknowledgement: Financial support from FAPERJ Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.

Authors

Institutions

Publication Details

Journal
Ultrasound in Obstetrics and Gynecology
Published
2024-09-01
DOI
https://doi.org/10.1002/uog.28384
Primary Topic
Renal and Vascular Pathologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EP09.03: Transposition of great arteries: three‐dimensional virtual and physical models from obstetrical ultrasound data

Gerson Ribeiro, Heron Werner, Edward Araujo Júnior, Nathalie Jeanne Bravo‐Valenzuela et al.
Ultrasound in Obstetrics and Gynecology
Renal and Vascular Pathologies
article

EP09.03: Transposition of great arteries: three‐dimensional virtual and physical models from obstetrical ultrasound data

Gerson Ribeiro, Heron Werner, Edward Araujo Júnior, Nathalie Jeanne Bravo‐Valenzuela, Caroline de Oliveira Nieblas, Marcela Castro Giffoni, J. Lopes
article en

Abstract

A diabetic 34-year-old woman, gravida 2 para 1, was referred for fetal echocardiography evaluation. During the fetal echocardiogram (25 weeks of gestation), abnormal outflow tracts showing a parallel course of the great arteries raised a strong suspicion of simple transposition of great arteries (TGA). The diagnosis was subsequently confirmed by the anatomical characteristics of the arteries that arose from each ventricle. Fetal echocardiogram was performed using a 3D high-resolution probe (4–8-MHz transducer, Voluson E9, GE Healthcare, Zipf, Austria). For post-processing images, software 3D Slicer (Birmington, UK) and Elucis (Realize Medical, Ottawa, ON, Canada) enabled the correct segmentation and texture improvement of the 3D US image. Using the software Elucis, we could segment the fetal heart in a virtual reality (VR) after import the images obtained through 4D-STIC and insert them into the application platform. A 3D model of the fetal heart was printed using a resin 3D printer (J5 MediJet 3D Printer Stratasys, USA). The 3D physical and virtual models were used in this case as interesting additional diagnostic tools to the current standard imaging armamentarium, enabling us to improve the quality of prenatal parental counselling and to optimise of cardiac surgical planning. The male neonate was born by Caesarean section and the surgical correction of TGA (arterial switch) was performed. Currently, he is clinically well, and has a mild aortic insufficiency. Acknowledgement: Financial support from FAPERJ Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.

Ultrasound in Obstetrics and GynecologyVol. 64(S1)
Universidade Federal do Rio de Janeiro (BR), Universidade Municipal de São Caetano do Sul (BR), Pontifícia Universidade Católica do Rio de Janeiro (BR), Universidade Federal de São Paulo (BR)
Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro
Openalex Percentile: Top 73%
Renal and Vascular Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.