EP09.07: Impact of sample volume position in calculating fetal cardiac output

Fetal cardiac output is known to assess fetal cardiac function, which is calculated using the cross-sectional area of the aortic valve and pulmonary valve and velocity time integral (VTI) with pulse Doppler. Although VTI is changed by the position of sample volume, on or distal to the valve, the impact to the cardiac output is unknown. Thirty-four patients were enrolled as normal fetal heart in fetal cardiology outpatients in our hospital. In recording VTI of the aortic and pulmonary valve, sample volume was positioned on the valve (valve group; V) and distal to the valve (supra-valve group; S). Cardiac output calculated by each VTI were compared. Additionally, electronic spatiotemporal image correlation (eSTIC) volume data was obtained from 17 patients and left ventricle cardiac output was calculated (eSTIC group). Correlation of left ventricle output calculated among eSTIC, V, and S groups was assessed. Aortic VTI was 8.5 ± 2.2cm vs 9.3 ± 2.5cm (Group V vs S, p < 0.01), and pulmonary VTI was 7.0 ± 1.7cm vs 8.2 ± 2.1cm (p < 0.01), suggesting that group S had significantly higher VTI. Combined output was 384 ± 125 vs 439 ± 140mL/kg/min, revealing that group S had significantly high cardiac output. Cardiac output of left ventricle was as follows; eSTIC group; 133 ± 69mL/kg/min, V group; 140 ± 73mL/kg/min, S group; 157 ± 77mL/kg/min. Correlation coefficient was 0.928, bias was -7.3 ± 27.4, and LOA was -61–46.4 between the eSTIC and V groups. Correlation coefficient was 0.917, bias was -24 ± 31, and LOA was -95–-37 between the eSTIC and S groups, showing that V group showed more similar results to eSTIC group. The position of sample volume has significant difference to cardiac output. Cardiac output measured by sample volume on the valve may be more accurate.

Authors

Institutions

Publication Details

Journal
Ultrasound in Obstetrics and Gynecology
Published
2024-09-01
DOI
https://doi.org/10.1002/uog.28388
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EP09.07: Impact of sample volume position in calculating fetal cardiac output

Kiyohiro Takigiku, K. Yonehara, Yohei Akazawa, Kohta Takei
Ultrasound in Obstetrics and Gynecology
Hemodynamic Monitoring and Therapy
article

EP09.07: Impact of sample volume position in calculating fetal cardiac output

Kiyohiro Takigiku, K. Yonehara, Yohei Akazawa, Kohta Takei
article en

Abstract

Fetal cardiac output is known to assess fetal cardiac function, which is calculated using the cross-sectional area of the aortic valve and pulmonary valve and velocity time integral (VTI) with pulse Doppler. Although VTI is changed by the position of sample volume, on or distal to the valve, the impact to the cardiac output is unknown. Thirty-four patients were enrolled as normal fetal heart in fetal cardiology outpatients in our hospital. In recording VTI of the aortic and pulmonary valve, sample volume was positioned on the valve (valve group; V) and distal to the valve (supra-valve group; S). Cardiac output calculated by each VTI were compared. Additionally, electronic spatiotemporal image correlation (eSTIC) volume data was obtained from 17 patients and left ventricle cardiac output was calculated (eSTIC group). Correlation of left ventricle output calculated among eSTIC, V, and S groups was assessed. Aortic VTI was 8.5 ± 2.2cm vs 9.3 ± 2.5cm (Group V vs S, p < 0.01), and pulmonary VTI was 7.0 ± 1.7cm vs 8.2 ± 2.1cm (p < 0.01), suggesting that group S had significantly higher VTI. Combined output was 384 ± 125 vs 439 ± 140mL/kg/min, revealing that group S had significantly high cardiac output. Cardiac output of left ventricle was as follows; eSTIC group; 133 ± 69mL/kg/min, V group; 140 ± 73mL/kg/min, S group; 157 ± 77mL/kg/min. Correlation coefficient was 0.928, bias was -7.3 ± 27.4, and LOA was -61–46.4 between the eSTIC and V groups. Correlation coefficient was 0.917, bias was -24 ± 31, and LOA was -95–-37 between the eSTIC and S groups, showing that V group showed more similar results to eSTIC group. The position of sample volume has significant difference to cardiac output. Cardiac output measured by sample volume on the valve may be more accurate.

Ultrasound in Obstetrics and GynecologyVol. 64(S1)
Nagano Children's Hospital (JP)
Openalex Percentile: Top 72%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

EP09.07: Impact of sample volume position in calculating fetal cardiac output — Kiyohiro Takigiku, K. Yonehara, et al. · Ultrasound in Obstetrics and Gynecology (2024) | TGRS Research Map | TGRS