EP01.03: Mobile‐based self‐operated ultrasound for fetal assessment in patients at or past the estimated date of delivery

According to literature, over 40% of women give birth after the estimated date of delivery (EDD). Management ranges from monitoring to intervention. Telemedicine is evolving and increasingly, self-operated portable devices are being used. In this study, we examined the INSTINCT device for fetal assessment in women past the EDD. Our aim was to evaluate whether the patient self-operated scans correlate with the routine scan. Secondly, we aimed to assess whether the mobile-based ultrasound system leads to a reduction in outpatient visits. In this prospective, observational trial, women included had a singleton fetus, and were at least at 40 + 0 gestational weeks. Each woman performed a set of scans with her device. An experienced sonographer performed the routine scans. The patients' scans were tested for fetal heart activity, amniotic fluid volume, and fetal body movements. They were classified, as normal if all parameters were in the reference range, abnormal if one or more parameters were out of the range or inadequate if, one or more parameters could not be evaluated. The women completed a questionnaire as well to evaluate satisfaction, safety and the question of reduction of outpatient visits. 50 women between 40 + 0 and 41 + 2 gestational weeks were included. 88% of the patients' scans were normal, 4% were abnormal and 8% were inadequate. 91,9% of the patients felt safe using the ultrasound device. 97,9% indicated that they would use such a device during pregnancy and in 81,6%, this would lead to a reduction of doctor's consultations. The overall satisfaction with the device 4, 65/5. The INSTINCT ultrasound system is a viable solution for remote fetal assessment and could potentially lead to a cost and time alleviation. There is need for integration of Doppler-mode to the device and for further studies with remote use. Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.

Authors

Institutions

Publication Details

Journal
Ultrasound in Obstetrics and Gynecology
Published
2024-09-01
DOI
https://doi.org/10.1002/uog.28018
Citations
1
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EP01.03: Mobile‐based self‐operated ultrasound for fetal assessment in patients at or past the estimated date of delivery

Wolfgang Henrich, S. S. Njonou Noujiep
1 citations
Ultrasound in Obstetrics and Gynecology
Ultrasound in Clinical Applications
0.42
article

EP01.03: Mobile‐based self‐operated ultrasound for fetal assessment in patients at or past the estimated date of delivery

Wolfgang Henrich, S. S. Njonou Noujiep
article en
1 citations

Abstract

According to literature, over 40% of women give birth after the estimated date of delivery (EDD). Management ranges from monitoring to intervention. Telemedicine is evolving and increasingly, self-operated portable devices are being used. In this study, we examined the INSTINCT device for fetal assessment in women past the EDD. Our aim was to evaluate whether the patient self-operated scans correlate with the routine scan. Secondly, we aimed to assess whether the mobile-based ultrasound system leads to a reduction in outpatient visits. In this prospective, observational trial, women included had a singleton fetus, and were at least at 40 + 0 gestational weeks. Each woman performed a set of scans with her device. An experienced sonographer performed the routine scans. The patients' scans were tested for fetal heart activity, amniotic fluid volume, and fetal body movements. They were classified, as normal if all parameters were in the reference range, abnormal if one or more parameters were out of the range or inadequate if, one or more parameters could not be evaluated. The women completed a questionnaire as well to evaluate satisfaction, safety and the question of reduction of outpatient visits. 50 women between 40 + 0 and 41 + 2 gestational weeks were included. 88% of the patients' scans were normal, 4% were abnormal and 8% were inadequate. 91,9% of the patients felt safe using the ultrasound device. 97,9% indicated that they would use such a device during pregnancy and in 81,6%, this would lead to a reduction of doctor's consultations. The overall satisfaction with the device 4, 65/5. The INSTINCT ultrasound system is a viable solution for remote fetal assessment and could potentially lead to a cost and time alleviation. There is need for integration of Doppler-mode to the device and for further studies with remote use. Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.

Ultrasound in Obstetrics and GynecologyVol. 64(S1)
Charité - Universitätsmedizin Berlin (DE)
Zero hunger
Openalex Percentile: Top 36%
Ultrasound in Clinical Applications
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.